TISO 35+: Thirty-five years with the TISO-10 PV plant: a statistical analysis of failure modes and their impact on safety and production

Mauro Caccivio; Alessandro Virtuani; Eleonora Annigoni

Institution
SUPSI PVLab and JRC ESTI (Pasan 3b flashers); EPFL PV-LAB, Switzerland
Equipment named
Pasan 3a/3b flashers; Pasan 3b (SUPSI PVLab); Pasan III B (JRC ESTI)
Application
Reference measurements of 18 reference modules to align a mobile LED flasher with the historical 1982 TISO-10 measurement chain.
Use
Intercomparison
Technologies
Field-aged modules
Venue
Swiss Federal Office of Energy SFOE, Final report (contract SI/501577-01), 2018

Significance

35-year field study where SUPSI and JRC Pasan 3b flashers anchored the metrology of a mobile flasher campaign.

From the source

“The measurement of 18 reference modules with Pasan 3b in SUPSI and Pasan 3b in JRC, with reference cells used in the past, gave confirmation from the metrological point of view on the good results from [the] portable flasher.”

Read the source

This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.