Results of the round robin calibration of reference solar cells within the PhotoClass project

Ingo Kröger et al. (PTB, JRC ESTI, Fraunhofer ISE, ISFH, SUPSI, CREST Loughborough, TÜV Rheinland, LNE)

Institution
EMRP PhotoClass consortium (8 European labs, anonymised as Laboratory#1-8), Europe
Equipment named
Pasan 3b pulsed sun simulator (Laboratories #3, #5, #7); pulsed solar simulator Pasan 3C (Laboratory #8)
Application
Calibration of WPVS-type c-Si and GaAs reference cells (ISTC) in a European intercomparison.
Use
Intercomparison
Technologies
Reference cells
Venue
International Journal of Metrology and Quality Engineering 9, 8, 2018

Significance

Four of the eight European calibration and testing laboratories in this EMRP intercomparison calibrated reference cells on Pasan simulators; all calibration values were consistent within stated uncertainties.

From the source

“Laboratory#3 uses an indoor calibration procedure with a Pasan 3b pulsed sun simulator (Class AAA).”