Tandem Solar Simulator for Power Measurement of Micromorph Tandem Modules

Vahid Fakhfouri et al.

Institution
Not stated; author affiliations Pasan SA (Neuchâtel), Oerlikon Solar AG (Trübbach), Oerlikon Solar-Lab SA (Neuchâtel), Photovoltaic Consultant (Freiburg), Switzerland (author affiliations)
Equipment named
Pasan High LIGHT electronic load; large-area tandem solar simulator with two independent, synchronized xenon flash lamps ('Blue' and 'Red')
Application
Development and qualification of a spectrally adjustable (±10% 'spectral swing') tandem simulator for Micromorph module power measurement at tandem STC, using top and bottom component cells
Use
Research
Technologies
Thin film, Multi-junction
Venue
Conference paper, 27th European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC 2012), pp. 2653-2656, 2012

Significance

Describes a dual-lamp tandem simulator reaching class A+ non-uniformity and spectrum over a 2x2 m2 test plane, with production-grade repeatability. Pasan staff are authors or co-authors of this work; it is Pasan research, not independent validation.

From the source

“A High LIGHT electronic load [6], with up to 4 irradiance measurement channels, is used to read out the outputs of the CoCells.”

Read the source

This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.