全部产品
旗舰平台
完整产品线
探索
联系我们

New guidelines for a more accurate extraction of solar cells and modules key data from their current–voltage curves

Bertrand Paviet‐Salomon et al.

Institution
CSEM PV-Center and Pasan SA (Meyer Burger Group), Neuchâtel, Switzerland
Equipment named
No equipment named in the public text; Pasan SA staff among the authors
Application
Optimisation of fit procedures for extracting Isc, Voc, FF, Pmax from I-V curves (numerical two-diode curves).
Use
Research
Technologies
Crystalline silicon
Venue
Progress in Photovoltaics: Research and Applications, 2017

Significance

Methodology paper on I-V key-data extraction co-authored by CSEM and Pasan R&D staff. Pasan staff are authors or co-authors of this work; it is Pasan research, not independent validation.

From the source

“Vahid Fakhfouri; Yanik Pelet; Nicolas Rebeaud: "Meyer Burger Group Pasan S.A. Rue Jaquet-Droz 8 Neuchâtel CH-2000 Switzerland"”

Read the source

This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.