محاكيات شمسية والمترولوجيا

منصة زينون واحدة تمتد من الخلية إلى الفضاء، إلى جانب الخيارات والمعايرة التي تُكمل القياس، IEC 60904-9 A+A+A+ و A++.

جميع المنتجات

Long-term power degradation analysis of crystalline silicon PV modules using indoor and outdoor measurement techniques

Fabian Carigiet; Christoph J. Brabec; Franz P. Baumgartner

Institution
ZHAW Zurich University of Applied Sciences (Swiss Mobile Flasher Bus), Switzerland
Equipment named
PASAN sun simulator 3c (installed in the Swiss Mobile Flasher Bus)
Application
Indoor-type STC flasher measurements of fielded modules over years for degradation-rate analysis; mobile on-site testing.
Use
Characterisation
Published uncertainty
Flasher Pmax measurement 3.2% (k = 2); 2011 comparison with JRC ESTI: max nominal power difference < 0.5%
Technologies
Degradation, Field-aged modules
Venue
Renewable and Sustainable Energy Reviews, 2021

Significance

Long-term degradation study using a mobile lab built around a Pasan SunSim 3c, cross-checked against JRC ESTI.

From the source

“a large Mercedes-Benz Sprinter Panel Van has been equipped with a commercial high-quality PASAN sun simulator 3c.”

Read the source

This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.

All entries