Knowledge Center · Scientific validation · Topics
Degradation and reliability: publications naming Pasan equipment
Reliability studies measure STC power before, during and after stress (damp heat, thermal cycling, UV, PID) or years in the field. The power loss is only as good as the repeatability of the indoor measurement.
23 publications · 23 institutions
- Intercomparison2018SUPSI PVLab and JRC ESTI (Pasan 3b flashers); EPFL PV-LABSwitzerland
TISO 35+: Thirty-five years with the TISO-10 PV plant: a statistical analysis of failure modes and their impact on safety and production
Equipment named: Pasan 3a/3b flashers; Pasan 3b (SUPSI PVLab); Pasan III B (JRC ESTI). Application: Reference measurements of 18 reference modules to align a mobile LED flasher with the historical 1982 TISO-10 measurement chain.
- Accredited testing2025Kiwa PI Berlin AGGermany
Topcon Solar Modules UV Degradation in Lab and Field Conditions
Equipment named: module flasher P@STC, with the Pasan SS3b. Application: Power measurement per IEC 61215-2 MQT 06 and IEC 60904-1 in UV-degradation testing of TOPCon modules.
- Accredited testing2025SUPSI PVLab (ISO 17025 accredited lab), with EPFL, TU Wien, OFISwitzerland
Three decades, three climates: environmental and material impacts on the long-term reliability of photovoltaic modules
Equipment named: class A+A+A+ 10-millisecond pulsed solar simulator (Pasan IIIb). Application: STC power measurement of modules after up to three decades outdoors in three climates.
- Accredited testing2023SUPSI PVLab (measurements for Politecnico di Milano)Switzerland / Italy
Long-term reliability of photovoltaic c-Si modules - A detailed assessment based on the first Italian BIPV project
Equipment named: AAA class Pasan Flasher. Application: Flash test of 20+-year-old BIPV modules (Feb 2022).
- Accredited testing2018PI Photovoltaik-Institut Berlin AG (PI Berlin), accredited test laboratory (ISO 17025), as statedGermany
PID issues in thin-film PV plants
Equipment named: Class AAA flasher Pasan SSIIIb. Application: STC I-V measurement of CdTe, CIGS and µc-Si thin-film modules from three PID-affected plants, before and after PID tests to IEC TS 62804-2 (85 °C, 85 % RH, maximum system voltage)
- Accredited testing2010SUPSI (laboratories in Lamone and Trevano)Switzerland
Lifetime, mechanical and safety testing for PV module certification (Schlussbericht)
Equipment named: PASAN IIIa flasher (class AAA, Lamone); PASAN IIIb (class AAA, Trevano). Application: Module test laboratory infrastructure for certification-type testing (STC, temperature coefficients).
- Characterisation2025Not stated (all authors: Department of Electrotechnology, Faculty of Electrical Engineering, Czech Technical University in Prague)Czech Republic (author affiliations)
The effect of backsheet repairs on insulation resistance in photovoltaic modules
Equipment named: Pasan IIIC flash solar simulator. Application: STC I-V characterisation of field-aged modules with degraded backsheets before rooftop installation, in a study of backsheet repairs and insulation resistance
- Characterisation2024Not stated (thesis, EPFL Photovoltaics and Thin-Film Electronics Laboratory; supervisors C. Ballif, A. Faes)Switzerland (author affiliations)
Advanced Manufacturing and Characterization of Building-Integrated Photovoltaic Modules
Equipment named: Horizontal PASAN solar simulator with LED and halogen lamps. Application: One-sun STC I-V measurement of BIPV mini-modules, including coated vs uncoated modules after UV exposure, with EL imaging
- Characterisation2024R&D Center TFTE LLC (measurements for UNSW / Oxford study)Russia
Ring Defects Associated with Boron-Oxygen-Related Degradation in p-Type Silicon Heterojunction Solar Cells
Equipment named: PASAN SpotLIGHT HighCap tester with GridTOUCH contacting. Application: J-V of busbarless SHJ cells at STC.
- Characterisation2022ICPE-CA (National Institute for R&D in Electrical Engineering), Laboratory of Photovoltaic SystemsRomania
Case Study Related to the Maintenance and On-Site Detection of Faulty Photovoltaic Panels in a 14 Years Old System Based on Thermal Camera
Equipment named: PASAN Highlight Solar Simulator. Application: STC laboratory tests of healthy and faulty panels from a 14-year-old system (with EL).
- Characterisation2021ZHAW Zurich University of Applied Sciences (Swiss Mobile Flasher Bus)Switzerland
Long-term power degradation analysis of crystalline silicon PV modules using indoor and outdoor measurement techniques
Equipment named: PASAN sun simulator 3c (installed in the Swiss Mobile Flasher Bus). Application: Indoor-type STC flasher measurements of fielded modules over years for degradation-rate analysis; mobile on-site testing.
- Characterisation2019"our laboratory" (not named; authors Fudan Univ., Xi’an Jiaotong Univ., CEPRI, Jiangsu Coast Development)China
Regular and Irregular Performance Variation of Module String and Occurred Conditions for Potential Induced Degradation-Affected Crystalline Silicon Photovoltaic Power Plants
Equipment named: PASAN Sunsim 3C. Application: STC I-V of PID-affected modules removed from PV plants.
- Characterisation2018Not stated for the flasher (authors include OFI, AIT, FH Technikum Wien)Austria
Climate specific accelerated ageing tests and evaluation of ageing induced electrical, physical, and chemical changes
Equipment named: PASAN HighLIGHT Very Large Module Tester flash cell tester. Application: STC power of test modules before, during and after climate-specific accelerated ageing.
- Characterisation2018Not stated for the flasher (authors: OFI, CTR, AIT Austrian Institute of Technology)Austria
Non-Destructive Failure Detection and Visualization of Artificially and Naturally Aged PV Modules
Equipment named: PASAN HighLIGHT VLMT A+A+A+ flasher (Very Large Module Tester). Application: STC power of artificially and naturally aged six-cell test modules before/after ageing.
- Characterisation2016Laboratório de Sistemas Fotovoltaicos, Instituto de Energia e Ambiente, Universidade de São Paulo (LSF-IEE/USP)Brazil
Impactos da degradação no desempenho elétrico e térmico de módulos fotovoltaicos de sistemas instalados em Minas Gerais
Equipment named: Solar simulator manufactured by Pasan ("Pasan Mesurent Systens verson R2.4.0"). Application: Flash testing of degraded field modules.
- Research2026Not stated (authors: Guangdong Univ. of Science and Technology, Central South Univ., Univ. of Macau)China
Degradation and Multi-Factor Effect on Photovoltaic Modules’ Characteristics Under Irregular Partial Shading Conditions
Equipment named: PASAN High LIGHT pulsed solar simulator testing system (Meyer Burger AG). Application: STC I-V/P-V characterisation of modules under controlled partial shading.
- Research2025Electricité de France (EDF R&D)France
Forecasting Photovoltaic Module Remaining Lifetime Using Accelerated Aging Testing and Modelling on Aged Modules
Equipment named: PASAN flash tester SunSim 3b with class AAA equipped with a Dragon Back system. Application: IV characterisation during IEC 61215 damp-heat testing of aged modules; same tester used since 2011 (then without DragonBack).
- Research2021Not explicitly stated ("in our experiment"; authors: Czech Technical University in Prague)Czech Republic
Diagnostics of PID Early Stage in PV Systems
Equipment named: PASAN Sun Simulator IIIc; Pasan IIIb; Pasan III flash tester. Application: I-V and Rs/Rsh tracking of modules during PID degradation and regeneration.
- Research2020Laboratório de Energia Solar (LABSOL), UFRGSBrazil
Análise da degradação induzida pelo potencial em módulos fotovoltaicos de silício cristalino
Equipment named: PASAN SunSim 3C (Large Area Pulsed Solar Simulator, A+A+A+). Application: STC I-V of crystalline modules in PID tests.
- Research2019Joint study: Sandia National Laboratories, Southern Research, Southern Company, EPRIUnited States
Predicting Photovoltaic Module Series Resistance based on Indoor-Aging Tests and Thermal Cycling Cumulative Exposure Estimates
Equipment named: Pasan IIIc solar simulator. Application: I-V measurements of modules after IEC 61215 TC200 / TC500 thermal cycling.
- Research2016European Commission JRC, ESTI, IspraItaly
Determination of internal series resistance of PV devices: repeatability and uncertainty
Equipment named: Pasan IIIB. Application: I-V curves at multiple irradiances for series-resistance determination (IEC 60891), compared across three large-area simulators.
- Research2013ECN Solar Energy, Petten (now TNO)Netherlands
Local deposition of Copper on Aluminum based MWT Back Contact Foil using Cold Spray Technology
Equipment named: Pasan IIIA flash-tester. Application: Module IV before/after IEC 61215 damp-heat and thermal-cycling tests.
- Research2012Not stated for the flasher (authors: EDF R&D, EDF Energies Nouvelles)France
Exploring highly accelerated aging on c-Si modules
Equipment named: PASAN flasher of AAA quality. Application: STC I-V of commercial modules during damp-heat 85/85 and 95/85 ageing.
These entries summarise third-party publications. They do not imply that the institutions or the authors endorse Pasan SA or its products.