Knowledge Center · Scientific validation · Topics
Reference cells and modules: publications naming Pasan equipment
Reference cells (WPVS type) and reference modules carry the traceable irradiance scale from a calibration laboratory to the simulator. Their spectral match to the device under test sets the mismatch correction.
11 publications · 10 institutions
- Secondary calibration2025UFSC / IFSC (simulator location not stated, likely LABSOL-UFRGS)Brazil
A Systematic Approach to Uncertainty Analysis in Reference Cell Calibration for Solar Irradiance Measurement
Equipment named: Pasan SunSim 3c, class AAA. Application: Indoor calibration of low-cost reference cells at STC as part of an uncertainty analysis.
- Secondary calibration2013TEL Solar metrology laboratory ('the company's metrology laboratory'); author affiliations TEL Solar-Lab SA (Neuchâtel), TEL Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Power Measurement Analysis of Micromorph Tandem Modules
Equipment named: modified solar simulator Pasan SunSim IIIb; Pasan electrical load with 16 bit data acquisition. Application: STC power measurement and calibration of Micromorph reference modules, a 'fading' multi-flash procedure for transient effects, and spectrometric assessment of tandem current matching
- Intercomparison2018EMRP PhotoClass consortium (8 European labs, anonymised as Laboratory#1-8)Europe
Results of the round robin calibration of reference solar cells within the PhotoClass project
Equipment named: Pasan 3b pulsed sun simulator (Laboratories #3, #5, #7); pulsed solar simulator Pasan 3C (Laboratory #8). Application: Calibration of WPVS-type c-Si and GaAs reference cells (ISTC) in a European intercomparison.
- Intercomparison2018SUPSI PVLab and JRC ESTI (Pasan 3b flashers); EPFL PV-LABSwitzerland
TISO 35+: Thirty-five years with the TISO-10 PV plant: a statistical analysis of failure modes and their impact on safety and production
Equipment named: Pasan 3a/3b flashers; Pasan 3b (SUPSI PVLab); Pasan III B (JRC ESTI). Application: Reference measurements of 18 reference modules to align a mobile LED flasher with the historical 1982 TISO-10 measurement chain.
- Intercomparison1998European Solar Test Installation (ESTI), Ispra (participant whose calibration method is described)Italy
The Results of the PEP'93 Intercomparison of Reference Cell Calibrations and Newer Technology Performance Measurements: Final Report
Equipment named: A Pasan pulsed solar simulator; the same simulator with interference filters for spectral response. Application: Secondary calibration of the World Photovoltaic Scale (WPVS) reference cell set against a calibrated reference cell, with spectral response measured for mismatch correction
- Accredited testing2016Laboratório de Sistemas Fotovoltaicos, IEE/USP, São PauloBrazil
Avaliação de conformidade de módulos fotovoltaicos: aplicação da Portaria INMETRO 004/2011
Equipment named: PASAN modelo HighLIGHT 3LMT (A+A+A+, 300 to 1200 nm). Application: INMETRO conformity assessment (Portaria 004/2011) of PV modules; reference module calibrated periodically at CIEMAT.
- Accredited testing2014SUPSI-ISAAC PVLab, CanobbioSwitzerland
Optimization of thin film module testing and PV module energy rating at SUPSI (Annual Report 2014)
Equipment named: Pasan IIIa and Pasan IIIb solar simulators (IIIb upgraded with LED floodlights for spectral tuning). Application: Spectral responsivity (27 filters on Pasan IIIa) and spectro-metric I-V of multi-junction modules on Pasan IIIb (accredited-lab procedure development).
- Characterisation2018LABSOL, UFRGSBrazil
CORREÇÃO ESPECTRAL E ANÁLISE DA INSTABILIDADE TEMPORAL EM SIMULADOR SOLAR PARA ENSAIOS DE MÓDULOS FOTOVOLTAICOS
Equipment named: SunSim 3C (PASAN, Meyer Burger Group). Application: Spectral mismatch correction with technology-matched reference cells and temporal-instability check of the simulator.
- Characterisation2016LABSOL, UFRGSBrazil
Qualificação espectral de simuladores solares para ensaios de módulos fotovoltaicos
Equipment named: SunSim 3C (PASAN, Meyer Burger Group). Application: Spectral qualification of the simulator using reference cells of different spectral response.
- Research2020Center for Physical Sciences and Technology (FTMC) / PROTECH, Vilnius (lab not named)Lithuania
Simple interference based colorization of Si based solar cells and panels with ITO/SiNx:H double layer antireflective coatings
Equipment named: PASAN highlight 3, AAA+ class solar simulator with WPVS monitor cell. Application: I-V of coloured modules.
- Research2011Oerlikon Solar (text: 'With installation at Oerlikon's site'; site not specified); author affiliations Oerlikon Solar-Lab SA (Neuchâtel), Oerlikon Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Traceable Flasher-Based Power Measurement of Micromorph Tandem Modules
Equipment named: commercial solar simulator SunSim IIIb (Pasan SA, CH), modified for tunable spectrum with a longitudinal sliding test bed. Application: Spectral balancing by lamp intensity and distance, with PTB-calibrated top and bottom component reference cells, for traceable STC power measurement of Micromorph tandem modules
These entries summarise third-party publications. They do not imply that the institutions or the authors endorse Pasan SA or its products.