- Institution
- TEL Solar metrology laboratory ('the company's metrology laboratory'); author affiliations TEL Solar-Lab SA (Neuchâtel), TEL Solar AG (Trübbach), Photovoltaic Consultant (Freiburg), Switzerland (author affiliations)
- Equipment named
- modified solar simulator Pasan SunSim IIIb; Pasan electrical load with 16 bit data acquisition
- Application
- STC power measurement and calibration of Micromorph reference modules, a 'fading' multi-flash procedure for transient effects, and spectrometric assessment of tandem current matching
- Use
- Secondary calibration
- Published uncertainty
- Expanded uncertainty (k=2) of 2.9% (2.89%) on Pmax at STC for Micromorph reference module calibration
- Technologies
- Thin film, Multi-junction
- Topics
- Venue
- Conference paper, 28th European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC 2013), pp. 3513-3518, 2013
Significance
Completes the uncertainty analysis of the tandem set-up and introduces an advanced multi-flash method, qualifying reference modules at 2.9% (k=2).
From the source
“The modified solar simulator Pasan SunSim IIIb, its spectral adjustment and the method of using traceable reference component cells were published in ref. 1.”
This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.