Knowledge Center · Scientific validation · Topics
Spectral mismatch: publications naming Pasan equipment
When the simulator spectrum differs from AM1.5G and the device and reference cell respond differently across it, the measured current is off by the spectral mismatch factor (IEC 60904-7). Correcting it needs the simulator spectrum and both spectral responses.
6 publications · 6 institutions
- Secondary calibration2013TEL Solar metrology laboratory ('the company's metrology laboratory'); author affiliations TEL Solar-Lab SA (Neuchâtel), TEL Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Power Measurement Analysis of Micromorph Tandem Modules
Equipment named: modified solar simulator Pasan SunSim IIIb; Pasan electrical load with 16 bit data acquisition. Application: STC power measurement and calibration of Micromorph reference modules, a 'fading' multi-flash procedure for transient effects, and spectrometric assessment of tandem current matching
- Intercomparison1998European Solar Test Installation (ESTI), Ispra (participant whose calibration method is described)Italy
The Results of the PEP'93 Intercomparison of Reference Cell Calibrations and Newer Technology Performance Measurements: Final Report
Equipment named: A Pasan pulsed solar simulator; the same simulator with interference filters for spectral response. Application: Secondary calibration of the World Photovoltaic Scale (WPVS) reference cell set against a calibrated reference cell, with spectral response measured for mismatch correction
- Accredited testing2014SUPSI-ISAAC PVLab, CanobbioSwitzerland
Optimization of thin film module testing and PV module energy rating at SUPSI (Annual Report 2014)
Equipment named: Pasan IIIa and Pasan IIIb solar simulators (IIIb upgraded with LED floodlights for spectral tuning). Application: Spectral responsivity (27 filters on Pasan IIIa) and spectro-metric I-V of multi-junction modules on Pasan IIIb (accredited-lab procedure development).
- Accredited testing2010Photovoltaik Institut Berlin (PI Berlin)Germany
Actual issues on power measurement of photovoltaic modules
Equipment named: Pasan SSIIIb (class A, 3.0 m x 3.0 m). Application: Reference simulator at PI Berlin in a study of uniformity, spectral mismatch, tandem current mismatch and sweep-time (transient) effects on Pmax of crystalline and thin-film modules (a-Si, micromorph tandem, CIGS).
- Characterisation2018LABSOL, UFRGSBrazil
CORREÇÃO ESPECTRAL E ANÁLISE DA INSTABILIDADE TEMPORAL EM SIMULADOR SOLAR PARA ENSAIOS DE MÓDULOS FOTOVOLTAICOS
Equipment named: SunSim 3C (PASAN, Meyer Burger Group). Application: Spectral mismatch correction with technology-matched reference cells and temporal-instability check of the simulator.
- Research2011Technische Universität Berlin (with PI Berlin)Germany
Spectral Mismatch Correction for Micromorph Tandem Modules
Equipment named: Pasan Flasher. Application: Spectral mismatch correction for micromorph tandem modules, compared with LED and steady-state simulators.