- Institution
- Photovoltaik Institut Berlin (PI Berlin), Germany
- Equipment named
- Pasan SSIIIb (class A, 3.0 m x 3.0 m)
- Application
- Reference simulator at PI Berlin in a study of uniformity, spectral mismatch, tandem current mismatch and sweep-time (transient) effects on Pmax of crystalline and thin-film modules (a-Si, micromorph tandem, CIGS).
- Use
- Accredited testing
- Published uncertainty
- Pmax ±2.2% (k = 2) for single-junction modules and 2.9% (k = 2) for tandem modules; measured uniformity ±0.3% on 3 m x 3 m
- Technologies
- Crystalline silicon, Thin film, Multi-junction, CIGS
- Topics
- Venue
- Photovoltaics International, 8th print edition, 2010
Significance
Independent test lab characterising its own Pasan SSIIIb: +/-0.3% uniformity on 3x3 m against the +/-2% class A limit.
From the source
“The measured uniformity of ±0.3% on a Pasan SSIIIb achieved that requirement very easily. [...] The maximum sweep time of the Pasan SSIIIb is 8ms, which proved to be sufficient for standard a-Si, mc-Si, and sc-Si modules (max. deviation of 0.5%).”
This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.