Knowledge Center · Scientific validation · Topics
Thin film: publications naming Pasan equipment
Thin-film modules (CdTe, CIGS, amorphous and micromorph silicon) are metastable: their power depends on the light and bias history, so preconditioning and spectral mismatch matter as much as the flash itself.
16 publications · 16 institutions
- Secondary calibration2013TEL Solar metrology laboratory ('the company's metrology laboratory'); author affiliations TEL Solar-Lab SA (Neuchâtel), TEL Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Power Measurement Analysis of Micromorph Tandem Modules
Equipment named: modified solar simulator Pasan SunSim IIIb; Pasan electrical load with 16 bit data acquisition. Application: STC power measurement and calibration of Micromorph reference modules, a 'fading' multi-flash procedure for transient effects, and spectrometric assessment of tandem current matching
- Accredited testing2018PI Photovoltaik-Institut Berlin AG (PI Berlin), accredited test laboratory (ISO 17025), as statedGermany
PID issues in thin-film PV plants
Equipment named: Class AAA flasher Pasan SSIIIb. Application: STC I-V measurement of CdTe, CIGS and µc-Si thin-film modules from three PID-affected plants, before and after PID tests to IEC TS 62804-2 (85 °C, 85 % RH, maximum system voltage)
- Accredited testing2014SUPSI-ISAAC PVLab, CanobbioSwitzerland
Optimization of thin film module testing and PV module energy rating at SUPSI (Annual Report 2014)
Equipment named: Pasan IIIa and Pasan IIIb solar simulators (IIIb upgraded with LED floodlights for spectral tuning). Application: Spectral responsivity (27 filters on Pasan IIIa) and spectro-metric I-V of multi-junction modules on Pasan IIIb (accredited-lab procedure development).
- Accredited testing2010Photovoltaik Institut Berlin (PI Berlin)Germany
Actual issues on power measurement of photovoltaic modules
Equipment named: Pasan SSIIIb (class A, 3.0 m x 3.0 m). Application: Reference simulator at PI Berlin in a study of uniformity, spectral mismatch, tandem current mismatch and sweep-time (transient) effects on Pmax of crystalline and thin-film modules (a-Si, micromorph tandem, CIGS).
- Accredited testing2008ISAAC, DACD, SUPSI, CanobbioSwitzerland
Quality and Energy Yield of Modules and Photovoltaic Plants (Qualita e resa energetica di moduli ed impianti fotovoltaici), centrale ISAAC-TISO periodo VII: 2003-2006, Final Report
Equipment named: Pasan IIIa pulsed solar simulator (class A, single xenon lamp 8 m from test area, Belval BV66 electronic load, data acquisition and software from the same manufacturer). Application: ISO 17025-accredited I-V measurement at STC of PV modules, temperature coefficients, I-V at various irradiances, inverse and multiflash I-V, thin-film module measurement
- Characterisation2024Not stated (thesis, EPFL Photovoltaics and Thin-Film Electronics Laboratory; supervisors C. Ballif, A. Faes)Switzerland (author affiliations)
Advanced Manufacturing and Characterization of Building-Integrated Photovoltaic Modules
Equipment named: Horizontal PASAN solar simulator with LED and halogen lamps. Application: One-sun STC I-V measurement of BIPV mini-modules, including coated vs uncoated modules after UV exposure, with EL imaging
- Characterisation2019European Commission JRC, ESTI, Ispra (measurements for a UPCT thesis)Italy / Spain
Caracterización térmica y eléctrica de tecnologías fotovoltaicas de lámina delgada para su integración arquitectónica en edificios (PhD thesis)
Equipment named: PASAN 3B flash simulator (class AAA, measuring area 3 m x 3 m and pulse duration 10 ms). Application: STC characterisation of a thin-film BIPV device at ESTI, single-flash vs multiflash, alongside the Apollo steady-state simulator.
- Characterisation2014ENEA C.R. Portici laboratory, as statedItaly
Energy Rating for Different Module Technologies
Equipment named: Solar simulator Pasan IIIB class AAA+ (realized by Belval). Application: STC flash test of mono-Si, multi-Si, quasi-mono and CIGS modules before outdoor energy-rating measurements
- Research2026Not stated for the flasher (thesis, University of Vienna; supervisor at AIT Austrian Institute of Technology)Austria
Short-Term Metastabilities and Power Rating in Thin-Film Photovoltaic Technologies
Equipment named: Pasan BV 66 active load and Pasan software for pulsed-light I-V measurement. Application: I-V measurement of amorphous silicon and micromorph modules during light-soaking pretreatment, and temperature correction of the curves, in a study of thin-film metastability and power rating
- Research2021AIT Austrian Institute of Technology, Vienna (experimental part); TU WienAustria
Purely electrical power stabilization of photovoltaic technologies
Equipment named: PASAN Flasher (class AAA pulsed solar simulator manufactured by PASAN). Application: STC I-V measurement of full-size CIGS and c-Si modules before/after dark-bias stabilisation experiments.
- Research2020Austrian Institute of Technology (AIT) PV testing facility (thesis states its test stands were used)Austria
Metastable effects in chalcogenide thin film photovoltaic devices
Equipment named: Pasan electronic load. Application: I-V characterisation of CdTe and CIGS modules during light soaking and metastability experiments on the AIT flasher and static sun simulator
- Research2015LABSOL, UFRGSBrazil
Desenvolvimento de metodologia e bancada para ensaio de exposição solar prolongada de módulos fotovoltaicos de filmes finos
Equipment named: PASAN model IIIc (A+A+A+, 2 m x 2 m). Application: I-V of thin-film modules during prolonged outdoor exposure tests.
- Research2012Not stated; author affiliations Pasan SA (Neuchâtel), Oerlikon Solar AG (Trübbach), Oerlikon Solar-Lab SA (Neuchâtel), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Tandem Solar Simulator for Power Measurement of Micromorph Tandem Modules
Equipment named: Pasan High LIGHT electronic load; large-area tandem solar simulator with two independent, synchronized xenon flash lamps ('Blue' and 'Red'). Application: Development and qualification of a spectrally adjustable (±10% 'spectral swing') tandem simulator for Micromorph module power measurement at tandem STC, using top and bottom component cells
- Research2011Oerlikon Solar (text: 'With installation at Oerlikon's site'; site not specified); author affiliations Oerlikon Solar-Lab SA (Neuchâtel), Oerlikon Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Traceable Flasher-Based Power Measurement of Micromorph Tandem Modules
Equipment named: commercial solar simulator SunSim IIIb (Pasan SA, CH), modified for tunable spectrum with a longitudinal sliding test bed. Application: Spectral balancing by lamp intensity and distance, with PTB-calibrated top and bottom component reference cells, for traceable STC power measurement of Micromorph tandem modules
- Research2011SUPSI ISAAC (with Pasan co-authors)Switzerland
Results of the MPVT (Multi-Purpose PV Module Tester) Project - A Highly Innovative and Versatile Solar Simulator
Equipment named: Pasan IIIB (existing pulsed solar-simulator based IV set-up). Application: Upgrade of the IIIB set-up with a new electronic load for thin-film and c-Si, dark IV and transient/capacitance measurements.
- Research2011Technische Universität Berlin (with PI Berlin)Germany
Spectral Mismatch Correction for Micromorph Tandem Modules
Equipment named: Pasan Flasher. Application: Spectral mismatch correction for micromorph tandem modules, compared with LED and steady-state simulators.
These entries summarise third-party publications. They do not imply that the institutions or the authors endorse Pasan SA or its products.