Knowledge Center · Scientific validation · Topics
Accelerated ageing (IEC 61215): publications naming Pasan equipment
IEC 61215 qualification and accelerated ageing (damp heat 85/85, thermal cycling, UV, humidity freeze) are bracketed by STC power measurements; the pass criterion is a power loss limit.
10 publications · 10 institutions
- Accredited testing2025Kiwa PI Berlin AGGermany
Topcon Solar Modules UV Degradation in Lab and Field Conditions
Equipment named: module flasher P@STC, with the Pasan SS3b. Application: Power measurement per IEC 61215-2 MQT 06 and IEC 60904-1 in UV-degradation testing of TOPCon modules.
- Accredited testing2018Photovoltaic Accredited Testing Center, Yeungnam UniversitySouth Korea
Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose
Equipment named: Pasan solar simulator (model not named). Application: Maximum power at STC per KS C IEC 61215 / 60904-1 after UV exposure.
- Characterisation2026CEA Liten, Campus INES; Universidad de Antofagasta (CDEA); Universidad de Granada; Universidad Tecnica Federico Santa Maria (author affiliations)France
Assessment of Soiling Dynamics and Cleaning Efficiency for Photovoltaic Modules Under Different Dust Environments
Equipment named: Class A+ PASAN solar simulator. Application: STC I-V characterisation (Isc, Pmax) of single-cell SHJ laminates before and after accelerated soiling and cleaning
- Characterisation2024Not stated (thesis, EPFL Photovoltaics and Thin-Film Electronics Laboratory; supervisors C. Ballif, A. Faes)Switzerland (author affiliations)
Advanced Manufacturing and Characterization of Building-Integrated Photovoltaic Modules
Equipment named: Horizontal PASAN solar simulator with LED and halogen lamps. Application: One-sun STC I-V measurement of BIPV mini-modules, including coated vs uncoated modules after UV exposure, with EL imaging
- Characterisation2018Not stated for the flasher (authors include OFI, AIT, FH Technikum Wien)Austria
Climate specific accelerated ageing tests and evaluation of ageing induced electrical, physical, and chemical changes
Equipment named: PASAN HighLIGHT Very Large Module Tester flash cell tester. Application: STC power of test modules before, during and after climate-specific accelerated ageing.
- Research2025Electricité de France (EDF R&D)France
Forecasting Photovoltaic Module Remaining Lifetime Using Accelerated Aging Testing and Modelling on Aged Modules
Equipment named: PASAN flash tester SunSim 3b with class AAA equipped with a Dragon Back system. Application: IV characterisation during IEC 61215 damp-heat testing of aged modules; same tester used since 2011 (then without DragonBack).
- Research2023Not stated (authors: EPFL PV-Lab, CSEM, PCCL, Czech Academy of Sciences)Switzerland
Stability of black interconnect coatings for solar photovoltaic module applications
Equipment named: PASAN solar simulator. Application: STC I-V of coated and uncoated mini-modules after UV exposure.
- Research2019Joint study: Sandia National Laboratories, Southern Research, Southern Company, EPRIUnited States
Predicting Photovoltaic Module Series Resistance based on Indoor-Aging Tests and Thermal Cycling Cumulative Exposure Estimates
Equipment named: Pasan IIIc solar simulator. Application: I-V measurements of modules after IEC 61215 TC200 / TC500 thermal cycling.
- Research2013ECN Solar Energy, Petten (now TNO)Netherlands
Local deposition of Copper on Aluminum based MWT Back Contact Foil using Cold Spray Technology
Equipment named: Pasan IIIA flash-tester. Application: Module IV before/after IEC 61215 damp-heat and thermal-cycling tests.
- Research2012Not stated for the flasher (authors: EDF R&D, EDF Energies Nouvelles)France
Exploring highly accelerated aging on c-Si modules
Equipment named: PASAN flasher of AAA quality. Application: STC I-V of commercial modules during damp-heat 85/85 and 95/85 ageing.
These entries summarise third-party publications. They do not imply that the institutions or the authors endorse Pasan SA or its products.