Knowledge Center · Scientific validation · Topics
Irradiance dependence and energy rating: publications naming Pasan equipment
Energy rating (IEC 61853) needs Pmax over a matrix of irradiances and temperatures, plus the angular response, not only at STC. Low-irradiance behaviour and temperature coefficients are part of it.
15 publications · 15 institutions
- Accredited testing2023CENER (National Renewable Energy Centre), accredited PV testing laboratorySpain
Multifunctional glasses and their application to photovoltaic technology
Equipment named: Pasan MFG Flash Generator (four Xe flashbulbs, 10 ms); Solar Flash Simulator IIIb from Pasan S. A.. Application: I-V and IAM (IEC 61853-2) characterisation of mini-modules with structured/antireflective glasses.
- Accredited testing2023CENER accredited testing laboratory (equipment described as accredited lab equipment; authors CENER)Spain
Outdoor Electrical Performance of Photovoltaic Mini‐Modules with Enhanced Broadband Omnidirectional Antireflective Nanostructured Glass
Equipment named: Solar Flash Simulator IIIb from Pasan S. A.. Application: I-V and IAM (IEC 61853-2) of mini-modules with nanostructured antireflective glass.
- Accredited testing2014SUPSI-ISAAC PVLab, CanobbioSwitzerland
Optimization of thin film module testing and PV module energy rating at SUPSI (Annual Report 2014)
Equipment named: Pasan IIIa and Pasan IIIb solar simulators (IIIb upgraded with LED floodlights for spectral tuning). Application: Spectral responsivity (27 filters on Pasan IIIa) and spectro-metric I-V of multi-junction modules on Pasan IIIb (accredited-lab procedure development).
- Accredited testing2010SUPSI (laboratories in Lamone and Trevano)Switzerland
Lifetime, mechanical and safety testing for PV module certification (Schlussbericht)
Equipment named: PASAN IIIa flasher (class AAA, Lamone); PASAN IIIb (class AAA, Trevano). Application: Module test laboratory infrastructure for certification-type testing (STC, temperature coefficients).
- Accredited testing2008ISAAC, DACD, SUPSI, CanobbioSwitzerland
Quality and Energy Yield of Modules and Photovoltaic Plants (Qualita e resa energetica di moduli ed impianti fotovoltaici), centrale ISAAC-TISO periodo VII: 2003-2006, Final Report
Equipment named: Pasan IIIa pulsed solar simulator (class A, single xenon lamp 8 m from test area, Belval BV66 electronic load, data acquisition and software from the same manufacturer). Application: ISO 17025-accredited I-V measurement at STC of PV modules, temperature coefficients, I-V at various irradiances, inverse and multiflash I-V, thin-film module measurement
- Characterisation2026Centre for Renewable Energy Systems Technology (CREST), Loughborough UniversityUnited Kingdom
CREST facilities page
Equipment named: pasan large area solar simulator. Application: PV module testing service, modified for low-light and angle-of-incidence measurements.
- Characterisation2024Not stated; all authors Universidade Federal do Rio Grande do Sul, Laboratório de Energia SolarBrazil (author affiliations)
Análise dos Coeficientes Térmicos de Módulos Fotovoltaicos Bifaciais Utilizando Simulador Solar e Iluminação Natural
Equipment named: SunSim 3c simulator from the Swiss company Pasan, with a purpose-built thermostatic chamber. Application: Indoor vs outdoor determination of temperature coefficients alpha, beta and gamma of a bifacial module, 25 to 65 °C at 1000 W/m2
- Characterisation2019AIT Austrian Institute of TechnologyAustria
Sondierung für PV-Fassadensysteme aus leichten Kunststoff-Modulen mit reversiblen Befestigungen für Neu- und Altbauten (PV-FAS_light+easy)
Equipment named: PASAN HighLIGHT solar simulator (3×3 m², pulsed, A+A+A+). Application: STC and low-irradiance power of lightweight façade modules on delivery and after 40 kWh light exposure.
- Characterisation2018LABSOL, Universidade Federal do Rio Grande do Sul (stated: simulator installed there)Brazil
Análise da Variação dos Coeficientes Térmicos de Módulos Fotovoltaicos com a Irradiância
Equipment named: LAPSS PASAN SunSim 3C. Application: Temperature coefficients alpha and beta of four c-Si modules at 75 to 1000 W/m2 and 25 to 65 °C, using a heating chamber in the simulator test plane
- Characterisation2016LABSOL, UFRGS, Porto AlegreBrazil
Variação da eficiência de módulos fotovoltaicos com a irradiância
Equipment named: LAPSS Modelo PASAN SunSim 3C (10 ms flash). Application: Module efficiency vs irradiance.
- Characterisation2014ENEA C.R. Portici laboratory, as statedItaly
Energy Rating for Different Module Technologies
Equipment named: Solar simulator Pasan IIIB class AAA+ (realized by Belval). Application: STC flash test of mono-Si, multi-Si, quasi-mono and CIGS modules before outdoor energy-rating measurements
- Research2016European Commission JRC, ESTI, IspraItaly
Determination of internal series resistance of PV devices: repeatability and uncertainty
Equipment named: Pasan IIIB. Application: I-V curves at multiple irradiances for series-resistance determination (IEC 60891), compared across three large-area simulators.
- Research2015ECN Solar Energy, Petten (now TNO)Netherlands
Light Trapping Film for Bifacial Applications
Equipment named: AAA Pasan SunSim 3b solar simulator. Application: Angular (0-85 deg) and bifacial module measurements inside the simulator.
- Research2014Not stated (all authors: TÜV Rheinland Energie und Umwelt GmbH, Cologne)Germany (author affiliations)
Solar Simulator Measurement Procedures for Determination of the Angular Characteristic of PV Modules
Equipment named: Pasan SunSim 3b pulsed solar simulator (4 xenon bulbs). Application: Indoor angular response (incidence angle modifier) measurement of full-size PV modules, non-destructive partial-shading method, as input to draft IEC 61853-2
- Research2010Pasan SASwitzerland
Evaluation of Commercial Large Area Solar Simulator: Features Exceeding the IEC Standard Class AAA
Equipment named: Latest generation of Pasan large-area flash solar simulators (with intensity-reduction mask and passband filters). Application: Manufacturer evaluation of spectral match, uniformity, temporal stability and incidence angle beyond IEC 60904-9 class AAA; low-irradiance and module spectral response options.
These entries summarise third-party publications. They do not imply that the institutions or the authors endorse Pasan SA or its products.