- Institution
- CENER (National Renewable Energy Centre), accredited PV testing laboratory, Spain
- Equipment named
- Pasan MFG Flash Generator (four Xe flashbulbs, 10 ms); Solar Flash Simulator IIIb from Pasan S. A.
- Application
- I-V and IAM (IEC 61853-2) characterisation of mini-modules with structured/antireflective glasses.
- Use
- Accredited testing
- Technologies
- Crystalline silicon
- Topics
- Venue
- PhD thesis, Universidad Pública de Navarra (UPNA), 2023
Significance
Compendium thesis on functional PV glasses, with mini-module I-V measured on CENER’s accredited Pasan equipment.
From the source
“A Pasan MFG Flash Generator was used. It works with a four Xe flashbulbs to provide an illumination essentially with the same spectral response than sunlight”
This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.