All-in-one module tester
I‑V, EL and HiPot. One station.
Place the module once. Get its power, its picture and its safety.
A Nexun EVO, PRO or PRO Max can be configured as an all-in-one tester. The I‑V flash measures the power, the electroluminescence camera images every cell, and the HiPot tester proves the insulation, one after the other, on the same bench. One scan, one placement, one result per module.
- I‑V curve
- EL picture
- HiPot result
Why one station
Three tests usually means three stations
On many lines the flash tester, the EL tester and the HiPot tester stand apart, each with its own conveyor transfer, its own software and its own file. Bringing them onto one bench changes that.
Handled once
The module is placed and contacted once. Fewer transfers mean less floor space and fewer chances to damage it.
One serial number, one record
The barcode is read once and the I‑V curve, the EL picture and the HiPot result are saved together under it. Nothing to match up afterwards.
One verdict
Pass or fail for the module, from all three tests, ready for your line control and your MES.
One software
Pasan Studio runs the flash, the camera and the tester, with one recipe per panel type.
The three tests
What each one tells you
- Power, Isc, Voc, FF
I‑V flash
Maximum power, Isc, Voc and fill factor under a full-LED solar simulator, from A+ A+ A+ (EVO) up to A++ A+ A++ (PRO and PRO Max) per IEC 60904-9.
Nexun systems - 65 MP, every cell
Electroluminescence
A 65-megapixel picture of the whole module at Isc and at a tenth of Isc, with an anomaly analysis that scores every cell: cracks, dark cells, finger and soldering defects.
Electroluminescence Imaging - Up to 6 kV
HiPot
Dielectric withstand up to 6 kV DC, insulation resistance and frame continuity, so every module ships insulated and bonded.
HiPot Testing
How it runs
From scan to verdict
Each test starts as soon as the previous one has released the module, not after processing or saving.
- The barcode is scanned and the module recipe is loaded. Scanning never starts a test: the module may not be in place yet.
- The I‑V flash measures the module.
- Electroluminescence starts as soon as the flash is over: the module is powered at Isc and at a tenth of Isc and the camera takes the pictures.
- When the EL supply has released the module, its leads switch to the HiPot tester and the test plan runs.
- The I‑V curve, the EL picture and the HiPot result are saved together, with one verdict for the module.
Pick your base
Three Nexun systems, one all-in-one configuration
The I‑V simulator is the base. Electroluminescence and HiPot are options you add to it.
Production linesNexun EVOA+ A+ A+Built for the factory: A+ A+ A+, cycle time down to 10 s for the flash, PLC, conveyor, barcode and MES integration. The natural base for an end-of-line all-in-one tester.
See the system
Labs and productionNexun PROA++ A+ A++Certification-grade silicon: 17 wavelengths, A++ A+ A++, 1.8 × 3 m and a 500 ms pulse for high-capacitance modules.
See the system
Flagship labNexun PRO MaxA++ A+ A++1300 W/m², 22 wavelengths, A++ A+ A++, for labs that want every test of a module on one bench.
See the systemYour choice
All in one, or only what you need
Every Nexun measures I‑V. Add electroluminescence, HiPot, or both, to match your quality plan. The station, the software and the record stay the same.
Questions we are often asked
What is an all-in-one PV module tester?
A single station that runs the I‑V flash test, the electroluminescence (EL) test and the HiPot safety test on a module without moving it, and saves the three results together.
Can I take only I‑V and EL, without HiPot?
Yes. EL and HiPot are separate options. The Nexun can test I‑V alone, I‑V with EL, I‑V with HiPot, or all three.
Does it connect to my production line?
The Nexun EVO is built for it: PLC signals, conveyors, barcode reading and MES integration. Tell us your line and we configure the station around it.
Which standards do the tests follow?
The I‑V flash is classified per IEC 60904-9. The EL pictures follow IEC TS 60904-13. The HiPot test is modelled on IEC 61215-2 MQT 03 and IEC 61730-2 MST 13 and MST 16, with the limits you set.
Rather we contact you?
Leave your email and we will get back to you. No form to fill in.
Power, picture and safety, in one placement.
Tell us your module format and your line, and we will propose the Nexun and the options that fit.