Thermal Chamber

TCS

Measure how a module behaves across its real operating range. The Pasan Thermal Conditioning System conditions full-size modules from 15 to 75 °C with ±1 °C uniformity, so temperature coefficients and the IEC 61853 matrix are measured in the same instrument, no transfer, no extra uncertainty.

Thermal Chamber15–75 °C · ±1 °C · IEC 61215 / 61853
15–75°C
Conditioning range
±1°C
Uniformity across module
3°C/min
Heating rate
4
Regulation zones (8 optional)
Temperature coefficients, done right

Power across the whole operating range.

A module's rating at 25 °C is only half the story; its energy yield depends on how power falls as it heats. The thermal chamber conditions the full module with ±1 °C uniformity so coefficients are measured cleanly, no thermal gradients, no estimation.

  • Range15 – 75 °C
  • Uniformity±1 °C
  • Heating / cooling3 / 1.5 °C per min
  • Stabilisation≈ 15 min
Integrated, not bolted on

On the same calibrated platform.

The TCS integrates directly with the HighLIGHT flasher and automated uniformity mapping, so a power measurement and its temperature coefficient come from one instrument and one calibration, to IEC 61215:2021 and the IEC 61853-1 matrix.

  • IntegrationHighLIGHT platform
  • Zones4 (8 optional)
  • StandardsIEC 61215 · 61853-1
  • Power19 kVA peak / 7 kVA avg