Knowledge Center · Scientific Validation & Reference Laboratories
Where Pasan equipment appears in the scientific record
Every entry is a publicly available source, read in full or in abstract, in which a laboratory names the Pasan equipment it used. Each entry records what the source says the equipment was used for, so that ownership is never confused with primary calibration.
115 entries · 106 institutions · 21 countries
- Secondary calibration2026European Commission JRC, European Solar Test Installation (ESTI), IspraItaly
European Solar Test Installation (ESTI), laboratory page
Equipment named: Pasan IIA pulsed solar simulator; Pasan IIIB pulsed solar simulator (3 m x 3 m test area). Application: Indoor facilities of the ISO/IEC 17025 (ACCREDIA no. 00465) PV calibration laboratory; the IIA is dedicated to spectral responsivity of single-junction devices.
- Secondary calibration2025UFSC / IFSC (simulator location not stated, likely LABSOL-UFRGS)Brazil
A Systematic Approach to Uncertainty Analysis in Reference Cell Calibration for Solar Irradiance Measurement
Equipment named: Pasan SunSim 3c, class AAA. Application: Indoor calibration of low-cost reference cells at STC as part of an uncertainty analysis.
- Secondary calibration2023Fraunhofer ISE, CalLab PV Modules (DAkkS D-K-11140-02-00), FreiburgGermany
Kalibrierschein / Calibration Certificate, sample (CalLab PV Modules)
Equipment named: Measurement system 'FL3 - Pasan HighLIGHT VLMT'; IV-curve tracer 'Pasan - CT506/HL3'. Application: Accredited calibration of PV modules at STC (sample certificate format).
- Secondary calibration2013European Commission JRC, ESTI, IspraItaly
Inside the Upgraded European Solar Test Installation PV Calibration Process
Equipment named: Pasan IIIB large-area pulsed simulator (3m x 3m). Application: Module calibration alongside the Apollo steady-state simulator; a third simulator is used to check transfer of calibrations made on the Apollo or Pasan to industrial conditions.
- Secondary calibration2013TEL Solar metrology laboratory ('the company's metrology laboratory'); author affiliations TEL Solar-Lab SA (Neuchâtel), TEL Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Power Measurement Analysis of Micromorph Tandem Modules
Equipment named: modified solar simulator Pasan SunSim IIIb; Pasan electrical load with 16 bit data acquisition. Application: STC power measurement and calibration of Micromorph reference modules, a 'fading' multi-flash procedure for transient effects, and spectrometric assessment of tandem current matching
- Intercomparison202210 laboratories and companies incl. TÜV Rheinland Shanghai, JRC ESTI, AIST, ISFH, SIMIT-CAS and Pasan SA (author affiliations)International
Interlaboratory comparison of voltage sweep methods used for the electrical characterization of encapsulated high‐efficiency c‐Si solar cells
Equipment named: No equipment named in the public text; Pasan SA staff among the authors. Application: Interlaboratory comparison of voltage-sweep methods for encapsulated high-efficiency c-Si cells.
- Intercomparison2019TÜV Rheinland (Shanghai, Japan, Cologne), JRC ESTI, SUPSI-ISAAC, Pasan SA (author affiliations)International (CN, JP, DE, IT, CH)
Electrical characterization intercomparison of high‐efficiency c‐Si modules within Asian and European laboratories
Equipment named: No equipment named in the public text; Pasan SA staff among the authors. Application: Round-robin of high-efficiency c-Si PV module I-V measurement between five ISO/IEC 17025 accredited labs and one industrial lab.
- Intercomparison2018EMRP PhotoClass consortium (8 European labs, anonymised as Laboratory#1-8)Europe
Results of the round robin calibration of reference solar cells within the PhotoClass project
Equipment named: Pasan 3b pulsed sun simulator (Laboratories #3, #5, #7); pulsed solar simulator Pasan 3C (Laboratory #8). Application: Calibration of WPVS-type c-Si and GaAs reference cells (ISTC) in a European intercomparison.
- Intercomparison2018SUPSI PVLab and JRC ESTI (Pasan 3b flashers); EPFL PV-LABSwitzerland
TISO 35+: Thirty-five years with the TISO-10 PV plant: a statistical analysis of failure modes and their impact on safety and production
Equipment named: Pasan 3a/3b flashers; Pasan 3b (SUPSI PVLab); Pasan III B (JRC ESTI). Application: Reference measurements of 18 reference modules to align a mobile LED flasher with the historical 1982 TISO-10 measurement chain.
- Intercomparison2016Six European and Asian laboratories (JRC ESTI among them)Europe / Asia
Electrical Performance Characterisation Intercomparison of High Efficiency c-Si PV Modules within European and Asian Laboratories
Equipment named: DragonBack (step-like I-V method). Application: Comparison of step-like methods (DragonBack, dynamic IV) against long-pulse, multi-flash and natural sunlight for high-efficiency c-Si modules.
- Intercomparison2011ZHAW (Swiss Mobile Flasher Bus) with JRC ESTISwitzerland / Italy
Intercomparison of Pulsed Solar Simulator Measurements between the Mobile Flasher Bus and Stationary Calibration Laboratories
Equipment named: Pasan 3c flasher (10 ms pulse) in the Swiss Mobile Flasher Bus. Application: Intercomparison of mobile on-site module power measurement against ESTI's stationary calibration laboratory.
- Intercomparison2007CIEMAT (Madrid), Fraunhofer ISE (Freiburg) and SUPSI (Lugano), as stated in Table 1Spain / Germany / Switzerland
Advanced intercomparison testing of PV modules in European test labs
Equipment named: Belval, Pasan IIIb (CIEMAT, Fraunhofer ISE); Belval, Pasan IIIa (SUPSI). Application: Round-robin STC power measurement of five crystalline silicon module types, high-efficiency modules included, among six European test laboratories (PERFORMANCE project); single-flash and multi-flash techniques
- Intercomparison1998European Solar Test Installation (ESTI), Ispra (participant whose calibration method is described)Italy
The Results of the PEP'93 Intercomparison of Reference Cell Calibrations and Newer Technology Performance Measurements: Final Report
Equipment named: A Pasan pulsed solar simulator; the same simulator with interference filters for spectral response. Application: Secondary calibration of the World Photovoltaic Scale (WPVS) reference cell set against a calibrated reference cell, with spectral response measured for mismatch correction
- Accredited testing2026SUPSI PVLab (ISAAC), Lugano/MendrisioSwitzerland
SUPSI PVLab activities (presentation)
Equipment named: N.3 Pasan Flasher, class AAA. Application: Electrical characterisation in the only Swiss ISO 17025 accredited PV module test lab; includes non-destructive module spectral response and LED spectrum fine-tuning.
- Accredited testing2025Kiwa PI Berlin AGGermany
Topcon Solar Modules UV Degradation in Lab and Field Conditions
Equipment named: module flasher P@STC, with the Pasan SS3b. Application: Power measurement per IEC 61215-2 MQT 06 and IEC 60904-1 in UV-degradation testing of TOPCon modules.
- Accredited testing2025SUPSI PVLab (ISO 17025 accredited lab), with EPFL, TU Wien, OFISwitzerland
Three decades, three climates: environmental and material impacts on the long-term reliability of photovoltaic modules
Equipment named: class A+A+A+ 10-millisecond pulsed solar simulator (Pasan IIIb). Application: STC power measurement of modules after up to three decades outdoors in three climates.
- Accredited testing2023CENER (authors; outdoor tests on CENER rooftop)Spain
Outdoor Thermal Performance of Photovoltaic Devices with Enhanced Daytime Radiative Cooling Glass
Equipment named: Solar Flash Simulator IIIb from Pasan S. A.. Application: Electrical parameters of mini-modules with radiative-cooling glass before outdoor monitoring.
- Accredited testing2023CENER (National Renewable Energy Centre), accredited PV testing laboratorySpain
Multifunctional glasses and their application to photovoltaic technology
Equipment named: Pasan MFG Flash Generator (four Xe flashbulbs, 10 ms); Solar Flash Simulator IIIb from Pasan S. A.. Application: I-V and IAM (IEC 61853-2) characterisation of mini-modules with structured/antireflective glasses.
- Accredited testing2023CENER accredited testing laboratory (equipment described as accredited lab equipment; authors CENER)Spain
Outdoor Electrical Performance of Photovoltaic Mini‐Modules with Enhanced Broadband Omnidirectional Antireflective Nanostructured Glass
Equipment named: Solar Flash Simulator IIIb from Pasan S. A.. Application: I-V and IAM (IEC 61853-2) of mini-modules with nanostructured antireflective glass.
- Accredited testing2023PV Evolution Labs (PVEL, now Kiwa PVEL), Berkeley CAUnited States
Bifacial PV Module Energy Modeling Validation Study (Final Technical Report, DE-EE0008546)
Equipment named: two Class A+A+A+ Pasan SunSim 3b pulsed solar simulators. Application: Initial and post-light-soaking STC flash testing of ~50 kWDC of mono- and bifacial PERC modules.
- Accredited testing2023SUPSI PVLab (measurements for Politecnico di Milano)Switzerland / Italy
Long-term reliability of photovoltaic c-Si modules - A detailed assessment based on the first Italian BIPV project
Equipment named: AAA class Pasan Flasher. Application: Flash test of 20+-year-old BIPV modules (Feb 2022).
- Accredited testing2022National Renewable Energy Centre (CENER), NavarraSpain
Random subwavelength structures on glass to improve photovoltaic module performance
Equipment named: Solar Flash Simulator IIIb from Pasan S.A.. Application: Electrical parameters of mini-modules with structured glass, on accredited lab equipment.
- Accredited testing2021CES Solar Cells Testing Center (CSSC), KMUTTThailand
Quantifying Soiling Accumulation on Photovoltaic Modules Using Standard Testing Results
Equipment named: Pasan solar simulator IIIb with class AAA. Application: STC performance measurement for soiling quantification.
- Accredited testing2018Photovoltaic Accredited Testing Center, Yeungnam UniversitySouth Korea
Characterization of Photovoltaic Module Encapsulant According to UV Irradiation Dose
Equipment named: Pasan solar simulator (model not named). Application: Maximum power at STC per KS C IEC 61215 / 60904-1 after UV exposure.
- Accredited testing2018PI Photovoltaik-Institut Berlin AG (PI Berlin), accredited test laboratory (ISO 17025), as statedGermany
PID issues in thin-film PV plants
Equipment named: Class AAA flasher Pasan SSIIIb. Application: STC I-V measurement of CdTe, CIGS and µc-Si thin-film modules from three PID-affected plants, before and after PID tests to IEC TS 62804-2 (85 °C, 85 % RH, maximum system voltage)
- Accredited testing2016Laboratório de Sistemas Fotovoltaicos, IEE/USP, São PauloBrazil
Avaliação de conformidade de módulos fotovoltaicos: aplicação da Portaria INMETRO 004/2011
Equipment named: PASAN modelo HighLIGHT 3LMT (A+A+A+, 300 to 1200 nm). Application: INMETRO conformity assessment (Portaria 004/2011) of PV modules; reference module calibrated periodically at CIEMAT.
- Accredited testing2014SUPSI ISAAC (Swiss PV Module Test Centre)Switzerland
30 Years of Experience with a 10 kW PV Plant
Equipment named: PASAN IIIa flash sun simulator (class AAA). Application: In-house IV measurement of field-aged modules from 2000; system accredited ISO 17025 in 2001 (before that, ESTI measured them 1981-2003).
- Accredited testing2014SUPSI-ISAAC PVLab, CanobbioSwitzerland
Optimization of thin film module testing and PV module energy rating at SUPSI (Annual Report 2014)
Equipment named: Pasan IIIa and Pasan IIIb solar simulators (IIIb upgraded with LED floodlights for spectral tuning). Application: Spectral responsivity (27 filters on Pasan IIIa) and spectro-metric I-V of multi-junction modules on Pasan IIIb (accredited-lab procedure development).
- Accredited testing2010Photovoltaik Institut Berlin (PI Berlin)Germany
Actual issues on power measurement of photovoltaic modules
Equipment named: Pasan SSIIIb (class A, 3.0 m x 3.0 m). Application: Reference simulator at PI Berlin in a study of uniformity, spectral mismatch, tandem current mismatch and sweep-time (transient) effects on Pmax of crystalline and thin-film modules (a-Si, micromorph tandem, CIGS).
- Accredited testing2010SUPSI (laboratories in Lamone and Trevano)Switzerland
Lifetime, mechanical and safety testing for PV module certification (Schlussbericht)
Equipment named: PASAN IIIa flasher (class AAA, Lamone); PASAN IIIb (class AAA, Trevano). Application: Module test laboratory infrastructure for certification-type testing (STC, temperature coefficients).
- Accredited testing2008ISAAC, DACD, SUPSI, CanobbioSwitzerland
Quality and Energy Yield of Modules and Photovoltaic Plants (Qualita e resa energetica di moduli ed impianti fotovoltaici), centrale ISAAC-TISO periodo VII: 2003-2006, Final Report
Equipment named: Pasan IIIa pulsed solar simulator (class A, single xenon lamp 8 m from test area, Belval BV66 electronic load, data acquisition and software from the same manufacturer). Application: ISO 17025-accredited I-V measurement at STC of PV modules, temperature coefficients, I-V at various irradiances, inverse and multiflash I-V, thin-film module measurement
- Accredited testing2006Korea Institute of Energy Research (KIER)South Korea
Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test
Equipment named: Pasan IIIb. Application: Domestic certification testing of PV modules; uncertainty analysis of I-V testing.
- Space2026ESA ESTEC, European Space Power LaboratoryNetherlands
ESPL - European Space Power Laboratory (Solar Generator Characterisation Facility)
Equipment named: Large Area Pulsed Solar Simulator - Pasan; Portable Mini-flasher (Pasan). Application: Absolute electrical characterisation of large solar panels up to 3 m; comparative measurements of coupons, panels and arrays.
- Characterisation2026CEA Liten, Campus INES; Universidad de Antofagasta (CDEA); Universidad de Granada; Universidad Tecnica Federico Santa Maria (author affiliations)France
Assessment of Soiling Dynamics and Cleaning Efficiency for Photovoltaic Modules Under Different Dust Environments
Equipment named: Class A+ PASAN solar simulator. Application: STC I-V characterisation (Isc, Pmax) of single-cell SHJ laminates before and after accelerated soiling and cleaning
- Characterisation2026Centre for Renewable Energy Systems Technology (CREST), Loughborough UniversityUnited Kingdom
CREST facilities page
Equipment named: pasan large area solar simulator. Application: PV module testing service, modified for low-light and angle-of-incidence measurements.
- Characterisation2026CIEMAT Solar PV Unit (authors); host of the simulator not explicitly statedSpain
Performance of Coloured Building-Integrated Photovoltaic Modules: A Three-Colour East-Oriented Façade
Equipment named: Pasan MFG 305–SunSim3CM. Application: STC I-V of coloured BIPV modules before façade installation, to set string power and mismatch.
- Characterisation2026Solar Energy Research Institute of Singapore (SERIS)Singapore
Stress and Fracture of Crystalline Silicon Solar Cell Interconnection Using Electrically Conductive Adhesive with Composite Metal Fillers for More Reliable Next Generation PV System Design
Equipment named: Pasan SunSim 3B. Application: Flash testing of single-cell module samples with ECA interconnection.
- Characterisation2025IEE - Institute of Energy and Environment, USPBrazil
Comparative analysis between provided values and measured values on photovoltaic modules
Equipment named: Solar Simulator HighLIGHT from Pasan Measurement Systems, version R2.4.0. Application: Flash test of poly- and mono-Si modules vs datasheet values.
- Characterisation2025Not stated (all authors: Department of Electrotechnology, Faculty of Electrical Engineering, Czech Technical University in Prague)Czech Republic (author affiliations)
The effect of backsheet repairs on insulation resistance in photovoltaic modules
Equipment named: Pasan IIIC flash solar simulator. Application: STC I-V characterisation of field-aged modules with degraded backsheets before rooftop installation, in a study of backsheet repairs and insulation resistance
- Characterisation2025Photovoltaic Module Quality Testing Laboratory (LPKMF), BRIN-PUSPIPTEKIndonesia
Analisis Perbandingan Performa Modul Surya Polycrystalline dan Monocrystalline Berkapasitas 320 Wp Menggunakan Perangkat Uji Sun Simulator PASAN
Equipment named: Sun Simulator Pasan test system. Application: STC performance of 320 Wp poly- and monocrystalline modules.
- Characterisation2024Not stated (thesis, EPFL Photovoltaics and Thin-Film Electronics Laboratory; supervisors C. Ballif, A. Faes)Switzerland (author affiliations)
Advanced Manufacturing and Characterization of Building-Integrated Photovoltaic Modules
Equipment named: Horizontal PASAN solar simulator with LED and halogen lamps. Application: One-sun STC I-V measurement of BIPV mini-modules, including coated vs uncoated modules after UV exposure, with EL imaging
- Characterisation2024Not stated; all authors Universidade Federal do Rio Grande do Sul, Laboratório de Energia SolarBrazil (author affiliations)
Análise dos Coeficientes Térmicos de Módulos Fotovoltaicos Bifaciais Utilizando Simulador Solar e Iluminação Natural
Equipment named: SunSim 3c simulator from the Swiss company Pasan, with a purpose-built thermostatic chamber. Application: Indoor vs outdoor determination of temperature coefficients alpha, beta and gamma of a bifacial module, 25 to 65 °C at 1000 W/m2
- Characterisation2024R&D Center TFTE LLC (measurements for UNSW / Oxford study)Russia
Ring Defects Associated with Boron-Oxygen-Related Degradation in p-Type Silicon Heterojunction Solar Cells
Equipment named: PASAN SpotLIGHT HighCap tester with GridTOUCH contacting. Application: J-V of busbarless SHJ cells at STC.
- Characterisation2023Not explicitly stated (authors: University of Cyprus PV Technology Laboratory; Sandia)Cyprus
Estimating the Performance Loss Rate of Photovoltaic Systems Using Time Series Change Point Analysis
Equipment named: Pasan SunSim IIIc. Application: Indoor STC measurement of modules from fielded systems for performance-loss-rate estimation.
- Characterisation2023Politehnica Bucharest / ICPE-CA (lab not named)Romania
Technical and economic analysis of commercial prosumer 30 kW + charging station for plug-in electric/hybrid cars 44 kW case study: Romania
Equipment named: Pasan Highlight solar simulator. Application: Laboratory verification of module datasheet power.
- Characterisation2022ICPE-CA (National Institute for R&D in Electrical Engineering), Laboratory of Photovoltaic SystemsRomania
Case Study Related to the Maintenance and On-Site Detection of Faulty Photovoltaic Panels in a 14 Years Old System Based on Thermal Camera
Equipment named: PASAN Highlight Solar Simulator. Application: STC laboratory tests of healthy and faulty panels from a 14-year-old system (with EL).
- Characterisation2021Not explicitly stated (authors: CEA-INES, USMB, Saint-Gobain Sekurit, EPFL PV-LAB)France
Color coated glazing for next generation BIPV: performance vs aesthetics
Equipment named: Pasan Measurement Systems HighLight 3 (Xenon 10 ms pulse, class A+A+A+, 8 m tunnel). Application: I-V characterisation of colour-coated BIPV modules including angle variations.
- Characterisation2021ZHAW Zurich University of Applied Sciences (Swiss Mobile Flasher Bus)Switzerland
Long-term power degradation analysis of crystalline silicon PV modules using indoor and outdoor measurement techniques
Equipment named: PASAN sun simulator 3c (installed in the Swiss Mobile Flasher Bus). Application: Indoor-type STC flasher measurements of fielded modules over years for degradation-rate analysis; mobile on-site testing.
- Characterisation2019"our laboratory" (not named; authors Fudan Univ., Xi’an Jiaotong Univ., CEPRI, Jiangsu Coast Development)China
Regular and Irregular Performance Variation of Module String and Occurred Conditions for Potential Induced Degradation-Affected Crystalline Silicon Photovoltaic Power Plants
Equipment named: PASAN Sunsim 3C. Application: STC I-V of PID-affected modules removed from PV plants.
- Characterisation2019AIT Austrian Institute of TechnologyAustria
Sondierung für PV-Fassadensysteme aus leichten Kunststoff-Modulen mit reversiblen Befestigungen für Neu- und Altbauten (PV-FAS_light+easy)
Equipment named: PASAN HighLIGHT solar simulator (3×3 m², pulsed, A+A+A+). Application: STC and low-irradiance power of lightweight façade modules on delivery and after 40 kWh light exposure.
- Characterisation2019European Commission JRC, ESTI, Ispra (measurements for a UPCT thesis)Italy / Spain
Caracterización térmica y eléctrica de tecnologías fotovoltaicas de lámina delgada para su integración arquitectónica en edificios (PhD thesis)
Equipment named: PASAN 3B flash simulator (class AAA, measuring area 3 m x 3 m and pulse duration 10 ms). Application: STC characterisation of a thin-film BIPV device at ESTI, single-flash vs multiflash, alongside the Apollo steady-state simulator.
- Characterisation2018LABSOL, UFRGSBrazil
CORREÇÃO ESPECTRAL E ANÁLISE DA INSTABILIDADE TEMPORAL EM SIMULADOR SOLAR PARA ENSAIOS DE MÓDULOS FOTOVOLTAICOS
Equipment named: SunSim 3C (PASAN, Meyer Burger Group). Application: Spectral mismatch correction with technology-matched reference cells and temporal-instability check of the simulator.
- Characterisation2018LABSOL, Universidade Federal do Rio Grande do Sul (stated: simulator installed there)Brazil
Análise da Variação dos Coeficientes Térmicos de Módulos Fotovoltaicos com a Irradiância
Equipment named: LAPSS PASAN SunSim 3C. Application: Temperature coefficients alpha and beta of four c-Si modules at 75 to 1000 W/m2 and 25 to 65 °C, using a heating chamber in the simulator test plane
- Characterisation2018Not stated for the flasher (authors include OFI, AIT, FH Technikum Wien)Austria
Climate specific accelerated ageing tests and evaluation of ageing induced electrical, physical, and chemical changes
Equipment named: PASAN HighLIGHT Very Large Module Tester flash cell tester. Application: STC power of test modules before, during and after climate-specific accelerated ageing.
- Characterisation2018Not stated for the flasher (authors: OFI, CTR, AIT Austrian Institute of Technology)Austria
Non-Destructive Failure Detection and Visualization of Artificially and Naturally Aged PV Modules
Equipment named: PASAN HighLIGHT VLMT A+A+A+ flasher (Very Large Module Tester). Application: STC power of artificially and naturally aged six-cell test modules before/after ageing.
- Characterisation2017Not stated (authors: imec, Leuven, Belgium; Kaneka Belgium N.V.)Belgium (author affiliations)
Progress in co-plating contacts for bifacial cells designed for multi-wire interconnection
Equipment named: Pasan GridTOUCH contact system (the light source is not a Pasan product). Application: Front/rear I-V characterisation of co-plated bifacial nPERT+ cells (M0 wafers) for multi-wire interconnection
- Characterisation2016CEA-INES Photovoltaic Modules Laboratory, Le Bourget-du-Lac; CNRS IMEP-LAHC, Grenoble Alpes University (author affiliations)France
A study of the annual performance of bifacial photovoltaic modules in the case of vertical facade integration
Equipment named: PASAN solar simulator (spectral class A+ per the authors' measurement). Application: Double-illumination (front and rear, mirrors) I-V characterisation of bifacial mini-modules; ray-tracing model of the simulator used to design the setup
- Characterisation2016Eurac Research laboratory, Bolzano (measurements for Politecnico di Milano)Italy
The first Italian BIPV project: Case study and long-term performance analysis
Equipment named: PASAN testing chamber. Application: STC I-V of modules removed from a 20-year-old BIPV array (IEC 60904).
- Characterisation2016Laboratório de Sistemas Fotovoltaicos, Instituto de Energia e Ambiente, Universidade de São Paulo (LSF-IEE/USP)Brazil
Impactos da degradação no desempenho elétrico e térmico de módulos fotovoltaicos de sistemas instalados em Minas Gerais
Equipment named: Solar simulator manufactured by Pasan ("Pasan Mesurent Systens verson R2.4.0"). Application: Flash testing of degraded field modules.
- Characterisation2016LABSOL, UFRGSBrazil
Qualificação espectral de simuladores solares para ensaios de módulos fotovoltaicos
Equipment named: SunSim 3C (PASAN, Meyer Burger Group). Application: Spectral qualification of the simulator using reference cells of different spectral response.
- Characterisation2016LABSOL, UFRGS, Porto AlegreBrazil
Variação da eficiência de módulos fotovoltaicos com a irradiância
Equipment named: LAPSS Modelo PASAN SunSim 3C (10 ms flash). Application: Module efficiency vs irradiance.
- Characterisation2015Brno University of TechnologyCzech Republic
Photovoltaic power plant inspection and diagnostic
Equipment named: Pasan SunSim 3C (A+/A+/A+). Application: STC reference values compared with field I-V analysers.
- Characterisation2015Laboratório de Energia Solar (LABSOL), UFRGSBrazil
Ensaios de módulos fotovoltaicos de distintas tecnologias com utilização de simulador solar
Equipment named: PASAN SunSim 3c. Application: I-V characterisation of ten modules of different technologies at varying irradiance.
- Characterisation2015Solar Energy Research Institute of Singapore (SERIS), PV module testing labSingapore
A linear method to extract diode model parameters of solar panels from a single I-V curve
Equipment named: pulsed solar simulator (PASAN IIIB). Application: I-V characterisation of full-size commercial modules for diode-parameter extraction.
- Characterisation2014ENEA C.R. Portici laboratory, as statedItaly
Energy Rating for Different Module Technologies
Equipment named: Solar simulator Pasan IIIB class AAA+ (realized by Belval). Application: STC flash test of mono-Si, multi-Si, quasi-mono and CIGS modules before outdoor energy-rating measurements
- Characterisation2013SUPSI ISAAC (measurements for TEC Costa Rica)Switzerland / Costa Rica
Celdas Solares que Contienen Tintes Sensibilizantes para la Producción de Energía (project report)
Equipment named: PASAN IIIB flasher (10 ms pulse-duration). Application: IV testing of PV modules with sweep-time study.
- Characterisation2012LABSOL, Universidade Federal do Rio Grande do Sul (UFRGS)Brazil
Análise de simuladores solares para ensaios de módulos fotovoltaicos
Equipment named: SunSim 3c (Pasan). Application: Selection of a module test simulator for the LABSOL lab after market comparison.
- Characterisation2010ENEA, UTTP FOTO Laboratory, Portici, as stated ("Pasan IIIb pulsed solar simulator at ENEA")Italy
Characterization of high‐efficiency c‐Si CPV cells
Equipment named: Pasan IIIb 10 ms pulsed solar simulator with a 28 cm Fresnel lens (concentrator stage). Application: I-V characterisation and linearity checks of high-efficiency c-Si CPV cells from 1X to about 250X, in an ESTI/ENEA intercomparison
- Characterisation2010ZHAW Zurich University of Applied Sciences (Swiss Mobile Flasher Bus)Switzerland
Swiss Mobile Flasher Bus: Progress and New Measurement Features
Equipment named: standard high-quality Pasan flasher. Application: On-site module power measurement, up to 200 modules/day, calibrated with modules measured at Fraunhofer ISE.
- Characterisation2008European Commission JRC, European Solar Test Installation (ESTI), Ispra, as stated in the thesisItaly
A MATLAB program for PV module performance analysis based on real outdoor data stored in a PostgreSQL database
Equipment named: "Pasan LAPSS" (single xenon lamp pulsed simulator, as written). Application: Indoor performance-surface (power matrix) measurements of PV modules at 25 to 60 °C and 50 to 1000 W/m² in a temperature-controlled chamber, used as input to an outdoor data analysis program
- Research2026Not stated (authors: Guangdong Univ. of Science and Technology and partners)China
Improved PSO-INC Algorithm for Maximum Power Point Tracking of Landscape-Oriented Photovoltaic Modules Under Dual-Peak Partial-Shading Conditions
Equipment named: PASAN HighLIGHT pulsed solar simulator. Application: Validation of an MPPT simulation model against earlier measured shading curves.
- Research2026Not stated (authors: Guangdong Univ. of Science and Technology, Central South Univ., Univ. of Macau)China
Degradation and Multi-Factor Effect on Photovoltaic Modules’ Characteristics Under Irregular Partial Shading Conditions
Equipment named: PASAN High LIGHT pulsed solar simulator testing system (Meyer Burger AG). Application: STC I-V/P-V characterisation of modules under controlled partial shading.
- Research2026Not stated (authors: Univ. de Antofagasta, Univ. of Granada, CEA Liten and others)Chile
Soiling in the Atacama Desert: Impacts on solar performance and evaluation of cleaning techniques
Equipment named: Pasan AAA-class simulator; PASAN HighLIGHT. Application: Isc of mini-modules before/after soiling and cleaning.
- Research2026Not stated for the flasher (thesis, University of Vienna; supervisor at AIT Austrian Institute of Technology)Austria
Short-Term Metastabilities and Power Rating in Thin-Film Photovoltaic Technologies
Equipment named: Pasan BV 66 active load and Pasan software for pulsed-light I-V measurement. Application: I-V measurement of amorphous silicon and micromorph modules during light-soaking pretreatment, and temperature correction of the curves, in a study of thin-film metastability and power rating
- Research2025Electricité de France (EDF R&D)France
Forecasting Photovoltaic Module Remaining Lifetime Using Accelerated Aging Testing and Modelling on Aged Modules
Equipment named: PASAN flash tester SunSim 3b with class AAA equipped with a Dragon Back system. Application: IV characterisation during IEC 61215 damp-heat testing of aged modules; same tester used since 2011 (then without DragonBack).
- Research2025Not stated (authors: Guangdong Univ. of Science and Technology and partners)China
Thin-Layer Dust Accumulation Effects on Photovoltaic Modules and Design Optimization for the Module Structure
Equipment named: PASAN High LIGHT system (developed by Meyer Burger). Application: STC I-V of modules with simulated edge dust shading.
- Research2025University of West Bohemia in PilsenCzech Republic
Influence of supplementary installed optical structures on VA characteristics of photovoltaic modules
Equipment named: modified flash tester unit Pasan Sun Simulator 2C. Application: STC I-V of modules with added optical structures.
- Research2024CEA Liten, INES campus (test benches)France
Quality assurance from laboratory to field: novel test solutions for soiling-prone PV systems
Equipment named: Class A+A+A+ PASAN solar simulator. Application: STC I-V of modules/laminates before and after artificial soiling cycles.
- Research2024Loughborough University laboratory (in collaboration); authors Cardiff UniversityUnited Kingdom
Electrical Faults Analysis and Detection in Photovoltaic Arrays Based on Machine Learning Classifiers
Equipment named: Pasan solar sun simulator. Application: Capture of I-V data of a small PV array for fault-classification machine-learning datasets.
- Research2023Institute for Solar Energy Research Hamelin (ISFH)Germany
Impact of the contacting scheme on I-V measurements of metallization-free silicon heterojunction solar cells
Equipment named: measurement system from Pasan SA, 30-wire contacting (PASAN Spotlight system). Application: Cell I-V of metallisation-free SHJ cells, compared with a second cell-measurement system.
- Research2023Not stated (authors: EPFL PV-Lab, CSEM, PCCL, Czech Academy of Sciences)Switzerland
Stability of black interconnect coatings for solar photovoltaic module applications
Equipment named: PASAN solar simulator. Application: STC I-V of coated and uncoated mini-modules after UV exposure.
- Research2023Not stated; author affiliations CSEM Sustainable Energy Center (Neuchâtel) and PASAN SA Technology and Product Center (Neuchâtel)Switzerland (author affiliations)
I-V Curve Simulation of Curved PV Modules for Vehicle Integration under various irradiation conditions
Equipment named: Conventional PASAN flasher (4.8 m and 8 m configurations considered in the model); PASAN tunnel flasher (planned validation). Application: Simulation model of I-V curves of curved VIPV modules under different flasher geometries and outdoor conditions, toward a power rating method for curved modules
- Research2022EPFL PV-Lab / CSEM, NeuchâtelSwitzerland
Transferability of the Light-Soaking Benefits on Silicon Heterojunction Cells to Modules
Equipment named: horizontal Pasan LED flasher with a 162x162 mm2 mask. Application: Module (one-cell) I-V after light soaking and lamination.
- Research2022European Commission JRC, ESTI, IspraItaly
Implementation of the IEC TS 60904-1-2 Measurement Methods for Bifacial Silicon PV Devices
Equipment named: class AAA PASAN IIIB PSS (pulse length of 10 ms). Application: Single-side illumination I-V measurements of bifacial devices (multiflash method) for IEC TS 60904-1-2 implementation.
- Research2022Not statedNot stated
Bifacial Photovoltaic Technology: Recent Advancements, Simulation and Performance Measurement
Equipment named: Pasan double-light-source bifacial solution (doubled multi-lamp xenon module simulator). Application: Review description of commercial double-sided illumination for bifacial module characterisation.
- Research2021AIT Austrian Institute of Technology, Vienna (experimental part); TU WienAustria
Purely electrical power stabilization of photovoltaic technologies
Equipment named: PASAN Flasher (class AAA pulsed solar simulator manufactured by PASAN). Application: STC I-V measurement of full-size CIGS and c-Si modules before/after dark-bias stabilisation experiments.
- Research2021Not explicitly stated ("in our experiment"; authors: Czech Technical University in Prague)Czech Republic
Diagnostics of PID Early Stage in PV Systems
Equipment named: PASAN Sun Simulator IIIc; Pasan IIIb; Pasan III flash tester. Application: I-V and Rs/Rsh tracking of modules during PID degradation and regeneration.
- Research2020Austrian Institute of Technology (AIT) PV testing facility (thesis states its test stands were used)Austria
Metastable effects in chalcogenide thin film photovoltaic devices
Equipment named: Pasan electronic load. Application: I-V characterisation of CdTe and CIGS modules during light soaking and metastability experiments on the AIT flasher and static sun simulator
- Research2020Center for Physical Sciences and Technology (FTMC) / PROTECH, Vilnius (lab not named)Lithuania
Simple interference based colorization of Si based solar cells and panels with ITO/SiNx:H double layer antireflective coatings
Equipment named: PASAN highlight 3, AAA+ class solar simulator with WPVS monitor cell. Application: I-V of coloured modules.
- Research2020Laboratório de Energia Solar (LABSOL), UFRGSBrazil
Análise da degradação induzida pelo potencial em módulos fotovoltaicos de silício cristalino
Equipment named: PASAN SunSim 3C (Large Area Pulsed Solar Simulator, A+A+A+). Application: STC I-V of crystalline modules in PID tests.
- Research2019Joint study: Sandia National Laboratories, Southern Research, Southern Company, EPRIUnited States
Predicting Photovoltaic Module Series Resistance based on Indoor-Aging Tests and Thermal Cycling Cumulative Exposure Estimates
Equipment named: Pasan IIIc solar simulator. Application: I-V measurements of modules after IEC 61215 TC200 / TC500 thermal cycling.
- Research2018LABSOL, UFRGS (Porto Alegre)Brazil
ANÁLISE DE DESEMPENHO E ATUAÇÃO DE DIODOS DE BYPASS EM UM MÓDULO FOTOVOLTAICO COMERCIAL
Equipment named: SunSim 3C (PASAN). Application: I-V of a commercial module to study bypass-diode operation under shading.
- Research2017CSEM PV-Center and Pasan SA (Meyer Burger Group), NeuchâtelSwitzerland
New guidelines for a more accurate extraction of solar cells and modules key data from their current–voltage curves
Equipment named: No equipment named in the public text; Pasan SA staff among the authors. Application: Optimisation of fit procedures for extracting Isc, Voc, FF, Pmax from I-V curves (numerical two-diode curves).
- Research2017Not stated; authors CREST, Loughborough UniversityUnited Kingdom (author affiliations)
Uncertainty contributions in photocurrent linearity measurements of PV devices using a flash solar simulator
Equipment named: Pasan 3B flash solar simulator, modified with an external 16 bit data acquisition system and four attenuation masks. Application: Photocurrent linearity measurement of PV devices from cells to full modules, with Monte Carlo uncertainty analysis
- Research2017Pasan SA (Meyer Burger Technology Group)Switzerland
IEC standard for power rating of bifacial PV devices
Equipment named: PCBTOUCH bifacial-compatible contacting solution; Pasan I-V equipment. Application: Describes the IEC 60904-1-2 project for bifacial I-V characterisation and power rating.
- Research2016ECN, Petten (now TNO)Netherlands
Production of Low Cost Back Contact Based PV Modules
Equipment named: PASAN IIIb flash tester. Application: Initial performance and IEC 61215 DH/TC testing of MWT mini-modules.
- Research2016European Commission JRC, ESTI, IspraItaly
Determination of internal series resistance of PV devices: repeatability and uncertainty
Equipment named: Pasan IIIB. Application: I-V curves at multiple irradiances for series-resistance determination (IEC 60891), compared across three large-area simulators.
- Research2015ECN Solar Energy, Petten (now TNO)Netherlands
Light Trapping Film for Bifacial Applications
Equipment named: AAA Pasan SunSim 3b solar simulator. Application: Angular (0-85 deg) and bifacial module measurements inside the simulator.
- Research2015LABSOL, UFRGSBrazil
Desenvolvimento de metodologia e bancada para ensaio de exposição solar prolongada de módulos fotovoltaicos de filmes finos
Equipment named: PASAN model IIIc (A+A+A+, 2 m x 2 m). Application: I-V of thin-film modules during prolonged outdoor exposure tests.
- Research2015University of Glasgow; Solar Energy Research Institute of Singapore (SERIS), NUS; REC Cells Pte Ltd (author affiliations)Singapore
A Linear Identification of Diode Models from Single I-V Characteristics of PV Panels
Equipment named: Pulsed solar simulator (PASAN IIIB), about 12 ms constant-intensity plateau. Application: Indoor flash I-V measurement of full-size commercial modules to validate a diode-model parameter extraction method
- Research2014Laboratório de Energia Solar, Universidade Federal do Rio Grande do Sul (stated: the laboratory acquired the simulator)Brazil
Estudo e Montagem de Túnel para Simulador Solar
Equipment named: SunSim 3c, supplied by PASAN (member of the Meyer Burger Group). Application: Design and construction of the tunnel housing the simulator (collimators, low-reflectance wall lining, air conditioning) for module characterisation and certification tests
- Research2014Not stated (all authors: TÜV Rheinland Energie und Umwelt GmbH, Cologne)Germany (author affiliations)
Solar Simulator Measurement Procedures for Determination of the Angular Characteristic of PV Modules
Equipment named: Pasan SunSim 3b pulsed solar simulator (4 xenon bulbs). Application: Indoor angular response (incidence angle modifier) measurement of full-size PV modules, non-destructive partial-shading method, as input to draft IEC 61853-2
- Research2014Not stated on the abstract pageNot stated
GridTOUCH: Innovative Solution for Accurate IV Measurement of Busbarless Cells in Production and Laboratory Environments
Equipment named: GridTOUCH system. Application: Contacting of busbarless cells for 4-terminal I-V measurement in production and labs; cell calibration method for accredited labs.
- Research2014Not stated; author affiliations CSEM, Meyer Burger AG, Somont, Roth&Rau Research, EPFL PV-LabSwitzerland (author affiliations)
SmartWire Solar Cell Interconnection Technology
Equipment named: GridTouch contacting (developed by Pasan). Application: I-V measurement of busbar-less silicon heterojunction cells (22.33% cell; low-Ag bifacial cells) before SmartWire module integration
- Research2013ECN Solar Energy, Petten (now TNO)Netherlands
Local deposition of Copper on Aluminum based MWT Back Contact Foil using Cold Spray Technology
Equipment named: Pasan IIIA flash-tester. Application: Module IV before/after IEC 61215 damp-heat and thermal-cycling tests.
- Research2013ECN, Petten (now TNO)Netherlands
Compatibility of copper-electroplated cells with metal wrap-through module materials
Equipment named: Pasan 3B flash tester. Application: Single-cell module performance within the FP7 Cu-PV project.
- Research2013PI Berlin (with Pasan co-authors)Germany
Performance Testing of High-Efficient PV Modules Using Single 10 ms Flash Pulses
Equipment named: DragonBack® method (customised voltage profile within one 10 ms flash). Application: Power determination of high-efficiency, high-capacitance modules; DragonBack compared with multi-flash.
- Research2012Not stated for the flasher (authors: EDF R&D, EDF Energies Nouvelles)France
Exploring highly accelerated aging on c-Si modules
Equipment named: PASAN flasher of AAA quality. Application: STC I-V of commercial modules during damp-heat 85/85 and 95/85 ageing.
- Research2012Not stated; author affiliations Pasan SA (Neuchâtel), Oerlikon Solar AG (Trübbach), Oerlikon Solar-Lab SA (Neuchâtel), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Tandem Solar Simulator for Power Measurement of Micromorph Tandem Modules
Equipment named: Pasan High LIGHT electronic load; large-area tandem solar simulator with two independent, synchronized xenon flash lamps ('Blue' and 'Red'). Application: Development and qualification of a spectrally adjustable (±10% 'spectral swing') tandem simulator for Micromorph module power measurement at tandem STC, using top and bottom component cells
- Research2012SUPSI (University of Applied Sciences and Arts of Southern Switzerland), as stated: the reference load is "available at SUPSI and part of its ISO-17025 accreditation system"Switzerland
Fast and accurate methods for the performance testing of highly-efficient c-Si photovoltaic modules using a 10 ms single-pulse solar simulator and customized voltage profiles
Equipment named: Pasan IIIB solar simulator (flash unit); Pasan BV66 electronic load; Pasan HIGH-LIGHT (HL) electronic load. Application: STC I-V testing of highly capacitive high-efficiency c-Si modules (HIT, back-contact) in one 10 ms flash with customized "dragon-back" voltage profiles, validated against multi-flash reference measurements
- Research2011Oerlikon Solar (text: 'With installation at Oerlikon's site'; site not specified); author affiliations Oerlikon Solar-Lab SA (Neuchâtel), Oerlikon Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Traceable Flasher-Based Power Measurement of Micromorph Tandem Modules
Equipment named: commercial solar simulator SunSim IIIb (Pasan SA, CH), modified for tunable spectrum with a longitudinal sliding test bed. Application: Spectral balancing by lamp intensity and distance, with PTB-calibrated top and bottom component reference cells, for traceable STC power measurement of Micromorph tandem modules
- Research2011SUPSI ISAAC (with Pasan co-authors)Switzerland
Results of the MPVT (Multi-Purpose PV Module Tester) Project - A Highly Innovative and Versatile Solar Simulator
Equipment named: Pasan IIIB (existing pulsed solar-simulator based IV set-up). Application: Upgrade of the IIIB set-up with a new electronic load for thin-film and c-Si, dark IV and transient/capacitance measurements.
- Research2011Technische Universität Berlin (with PI Berlin)Germany
Spectral Mismatch Correction for Micromorph Tandem Modules
Equipment named: Pasan Flasher. Application: Spectral mismatch correction for micromorph tandem modules, compared with LED and steady-state simulators.
- Research2010Pasan SASwitzerland
Evaluation of Commercial Large Area Solar Simulator: Features Exceeding the IEC Standard Class AAA
Equipment named: Latest generation of Pasan large-area flash solar simulators (with intensity-reduction mask and passband filters). Application: Manufacturer evaluation of spectral match, uniformity, temporal stability and incidence angle beyond IEC 60904-9 class AAA; low-irradiance and module spectral response options.
- Research2008Pasan SA, Neuchâtel (author affiliation; measurements made on Pasan sun simulators)Switzerland
Mastering the Spectrum in Class A Pulsed Solar Simulators
Equipment named: Pasan solar simulators with custom xenon long-arc flash tubes and custom interferential filters; customised Avantes dual-channel spectrometer. Application: Design of interferential filters for AM1.5 spectral match of 10 ms pulsed simulators, and time-resolved spectral measurement during the flash
How this database is built
- Sources: peer-reviewed papers, conference proceedings, theses, laboratory reports and laboratory web pages that are publicly accessible.
- Inclusion: the source names Pasan equipment (by brand or model) in connection with the institution, and a short verbatim quote proving it is recorded with the entry.
- Use is recorded as the source states it: primary calibration, secondary calibration, accredited testing, characterisation, research, production, space or intercomparison. Using a Pasan simulator does not make a laboratory's results a primary calibration, and owning one is not an endorsement.
- Nothing is inferred: no customer list, sales record or private communication is used. Leads that could not be verified from a public source are not published.
- Corrections: if an entry misstates a source, write to info@pasan.ch and it will be corrected or removed.