Knowledge Center · Scientific validation · Topics
Field-aged modules: publications naming Pasan equipment
Modules taken back from installations after years or decades in the field are measured indoors at STC to obtain degradation rates and failure modes.
20 publications · 19 institutions
- Intercomparison2018SUPSI PVLab and JRC ESTI (Pasan 3b flashers); EPFL PV-LABSwitzerland
TISO 35+: Thirty-five years with the TISO-10 PV plant: a statistical analysis of failure modes and their impact on safety and production
Equipment named: Pasan 3a/3b flashers; Pasan 3b (SUPSI PVLab); Pasan III B (JRC ESTI). Application: Reference measurements of 18 reference modules to align a mobile LED flasher with the historical 1982 TISO-10 measurement chain.
- Accredited testing2025Kiwa PI Berlin AGGermany
Topcon Solar Modules UV Degradation in Lab and Field Conditions
Equipment named: module flasher P@STC, with the Pasan SS3b. Application: Power measurement per IEC 61215-2 MQT 06 and IEC 60904-1 in UV-degradation testing of TOPCon modules.
- Accredited testing2025SUPSI PVLab (ISO 17025 accredited lab), with EPFL, TU Wien, OFISwitzerland
Three decades, three climates: environmental and material impacts on the long-term reliability of photovoltaic modules
Equipment named: class A+A+A+ 10-millisecond pulsed solar simulator (Pasan IIIb). Application: STC power measurement of modules after up to three decades outdoors in three climates.
- Accredited testing2018PI Photovoltaik-Institut Berlin AG (PI Berlin), accredited test laboratory (ISO 17025), as statedGermany
PID issues in thin-film PV plants
Equipment named: Class AAA flasher Pasan SSIIIb. Application: STC I-V measurement of CdTe, CIGS and µc-Si thin-film modules from three PID-affected plants, before and after PID tests to IEC TS 62804-2 (85 °C, 85 % RH, maximum system voltage)
- Accredited testing2014SUPSI ISAAC (Swiss PV Module Test Centre)Switzerland
30 Years of Experience with a 10 kW PV Plant
Equipment named: PASAN IIIa flash sun simulator (class AAA). Application: In-house IV measurement of field-aged modules from 2000; system accredited ISO 17025 in 2001 (before that, ESTI measured them 1981-2003).
- Accredited testing2008ISAAC, DACD, SUPSI, CanobbioSwitzerland
Quality and Energy Yield of Modules and Photovoltaic Plants (Qualita e resa energetica di moduli ed impianti fotovoltaici), centrale ISAAC-TISO periodo VII: 2003-2006, Final Report
Equipment named: Pasan IIIa pulsed solar simulator (class A, single xenon lamp 8 m from test area, Belval BV66 electronic load, data acquisition and software from the same manufacturer). Application: ISO 17025-accredited I-V measurement at STC of PV modules, temperature coefficients, I-V at various irradiances, inverse and multiflash I-V, thin-film module measurement
- Characterisation2026CIEMAT Solar PV Unit (authors); host of the simulator not explicitly statedSpain
Performance of Coloured Building-Integrated Photovoltaic Modules: A Three-Colour East-Oriented Façade
Equipment named: Pasan MFG 305–SunSim3CM. Application: STC I-V of coloured BIPV modules before façade installation, to set string power and mismatch.
- Characterisation2025Not stated (all authors: Department of Electrotechnology, Faculty of Electrical Engineering, Czech Technical University in Prague)Czech Republic (author affiliations)
The effect of backsheet repairs on insulation resistance in photovoltaic modules
Equipment named: Pasan IIIC flash solar simulator. Application: STC I-V characterisation of field-aged modules with degraded backsheets before rooftop installation, in a study of backsheet repairs and insulation resistance
- Characterisation2023Not explicitly stated (authors: University of Cyprus PV Technology Laboratory; Sandia)Cyprus
Estimating the Performance Loss Rate of Photovoltaic Systems Using Time Series Change Point Analysis
Equipment named: Pasan SunSim IIIc. Application: Indoor STC measurement of modules from fielded systems for performance-loss-rate estimation.
- Characterisation2022ICPE-CA (National Institute for R&D in Electrical Engineering), Laboratory of Photovoltaic SystemsRomania
Case Study Related to the Maintenance and On-Site Detection of Faulty Photovoltaic Panels in a 14 Years Old System Based on Thermal Camera
Equipment named: PASAN Highlight Solar Simulator. Application: STC laboratory tests of healthy and faulty panels from a 14-year-old system (with EL).
- Characterisation2021ZHAW Zurich University of Applied Sciences (Swiss Mobile Flasher Bus)Switzerland
Long-term power degradation analysis of crystalline silicon PV modules using indoor and outdoor measurement techniques
Equipment named: PASAN sun simulator 3c (installed in the Swiss Mobile Flasher Bus). Application: Indoor-type STC flasher measurements of fielded modules over years for degradation-rate analysis; mobile on-site testing.
- Characterisation2019"our laboratory" (not named; authors Fudan Univ., Xi’an Jiaotong Univ., CEPRI, Jiangsu Coast Development)China
Regular and Irregular Performance Variation of Module String and Occurred Conditions for Potential Induced Degradation-Affected Crystalline Silicon Photovoltaic Power Plants
Equipment named: PASAN Sunsim 3C. Application: STC I-V of PID-affected modules removed from PV plants.
- Characterisation2016Eurac Research laboratory, Bolzano (measurements for Politecnico di Milano)Italy
The first Italian BIPV project: Case study and long-term performance analysis
Equipment named: PASAN testing chamber. Application: STC I-V of modules removed from a 20-year-old BIPV array (IEC 60904).
- Characterisation2016Laboratório de Sistemas Fotovoltaicos, Instituto de Energia e Ambiente, Universidade de São Paulo (LSF-IEE/USP)Brazil
Impactos da degradação no desempenho elétrico e térmico de módulos fotovoltaicos de sistemas instalados em Minas Gerais
Equipment named: Solar simulator manufactured by Pasan ("Pasan Mesurent Systens verson R2.4.0"). Application: Flash testing of degraded field modules.
- Characterisation2015Brno University of TechnologyCzech Republic
Photovoltaic power plant inspection and diagnostic
Equipment named: Pasan SunSim 3C (A+/A+/A+). Application: STC reference values compared with field I-V analysers.
- Research2026Not stated (authors: Guangdong Univ. of Science and Technology and partners)China
Improved PSO-INC Algorithm for Maximum Power Point Tracking of Landscape-Oriented Photovoltaic Modules Under Dual-Peak Partial-Shading Conditions
Equipment named: PASAN HighLIGHT pulsed solar simulator. Application: Validation of an MPPT simulation model against earlier measured shading curves.
- Research2026Not stated (authors: Guangdong Univ. of Science and Technology, Central South Univ., Univ. of Macau)China
Degradation and Multi-Factor Effect on Photovoltaic Modules’ Characteristics Under Irregular Partial Shading Conditions
Equipment named: PASAN High LIGHT pulsed solar simulator testing system (Meyer Burger AG). Application: STC I-V/P-V characterisation of modules under controlled partial shading.
- Research2025Not stated (authors: Guangdong Univ. of Science and Technology and partners)China
Thin-Layer Dust Accumulation Effects on Photovoltaic Modules and Design Optimization for the Module Structure
Equipment named: PASAN High LIGHT system (developed by Meyer Burger). Application: STC I-V of modules with simulated edge dust shading.
- Research2024CEA Liten, INES campus (test benches)France
Quality assurance from laboratory to field: novel test solutions for soiling-prone PV systems
Equipment named: Class A+A+A+ PASAN solar simulator. Application: STC I-V of modules/laminates before and after artificial soiling cycles.
- Research2018LABSOL, UFRGS (Porto Alegre)Brazil
ANÁLISE DE DESEMPENHO E ATUAÇÃO DE DIODOS DE BYPASS EM UM MÓDULO FOTOVOLTAICO COMERCIAL
Equipment named: SunSim 3C (PASAN). Application: I-V of a commercial module to study bypass-diode operation under shading.
These entries summarise third-party publications. They do not imply that the institutions or the authors endorse Pasan SA or its products.