- Institution
- Kiwa PI Berlin AG, Germany
- Equipment named
- module flasher P@STC, with the Pasan SS3b
- Application
- Power measurement per IEC 61215-2 MQT 06 and IEC 60904-1 in UV-degradation testing of TOPCon modules.
- Use
- Accredited testing
- Published uncertainty
- Reproducibility +/-0.6% for Pmpp, Voc and Isc
- Technologies
- TOPCon, Degradation, Field-aged modules
- Topics
- Venue
- 40. PV-Symposium 2025 (TIB Open Publishing), 2025
Significance
Shows a Pasan SS3b still in use at Kiwa PI Berlin in 2025 for TOPCon reliability testing.
From the source
“The power measurements were conducted using a module flasher P@STC, with the Pasan SS3b being employed.”
This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.