A measurement uncertainty budget (GUM, k = 2) states how far the reported Pmax may be from the true value. Sources here quantify uncertainty or repeatability with Pasan equipment.
26 publications · 25 institutions
- Secondary calibration2025UFSC / IFSC (simulator location not stated, likely LABSOL-UFRGS)Brazil
A Systematic Approach to Uncertainty Analysis in Reference Cell Calibration for Solar Irradiance Measurement
Equipment named: Pasan SunSim 3c, class AAA. Application: Indoor calibration of low-cost reference cells at STC as part of an uncertainty analysis.
- Secondary calibration2023Fraunhofer ISE, CalLab PV Modules (DAkkS D-K-11140-02-00), FreiburgGermany
Kalibrierschein / Calibration Certificate, sample (CalLab PV Modules)
Equipment named: Measurement system 'FL3 - Pasan HighLIGHT VLMT'; IV-curve tracer 'Pasan - CT506/HL3'. Application: Accredited calibration of PV modules at STC (sample certificate format).
- Secondary calibration2013TEL Solar metrology laboratory ('the company's metrology laboratory'); author affiliations TEL Solar-Lab SA (Neuchâtel), TEL Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Power Measurement Analysis of Micromorph Tandem Modules
Equipment named: modified solar simulator Pasan SunSim IIIb; Pasan electrical load with 16 bit data acquisition. Application: STC power measurement and calibration of Micromorph reference modules, a 'fading' multi-flash procedure for transient effects, and spectrometric assessment of tandem current matching
- Intercomparison2019TÜV Rheinland (Shanghai, Japan, Cologne), JRC ESTI, SUPSI-ISAAC, Pasan SA (author affiliations)International (CN, JP, DE, IT, CH)
Electrical characterization intercomparison of high‐efficiency c‐Si modules within Asian and European laboratories
Equipment named: No equipment named in the public text; Pasan SA staff among the authors. Application: Round-robin of high-efficiency c-Si PV module I-V measurement between five ISO/IEC 17025 accredited labs and one industrial lab.
- Intercomparison2011ZHAW (Swiss Mobile Flasher Bus) with JRC ESTISwitzerland / Italy
Intercomparison of Pulsed Solar Simulator Measurements between the Mobile Flasher Bus and Stationary Calibration Laboratories
Equipment named: Pasan 3c flasher (10 ms pulse) in the Swiss Mobile Flasher Bus. Application: Intercomparison of mobile on-site module power measurement against ESTI's stationary calibration laboratory.
- Accredited testing2026SUPSI PVLab (ISAAC), Lugano/MendrisioSwitzerland
SUPSI PVLab activities (presentation)
Equipment named: N.3 Pasan Flasher, class AAA. Application: Electrical characterisation in the only Swiss ISO 17025 accredited PV module test lab; includes non-destructive module spectral response and LED spectrum fine-tuning.
- Accredited testing2025SUPSI PVLab (ISO 17025 accredited lab), with EPFL, TU Wien, OFISwitzerland
Three decades, three climates: environmental and material impacts on the long-term reliability of photovoltaic modules
Equipment named: class A+A+A+ 10-millisecond pulsed solar simulator (Pasan IIIb). Application: STC power measurement of modules after up to three decades outdoors in three climates.
- Accredited testing2023SUPSI PVLab (measurements for Politecnico di Milano)Switzerland / Italy
Long-term reliability of photovoltaic c-Si modules - A detailed assessment based on the first Italian BIPV project
Equipment named: AAA class Pasan Flasher. Application: Flash test of 20+-year-old BIPV modules (Feb 2022).
- Accredited testing2021CES Solar Cells Testing Center (CSSC), KMUTTThailand
Quantifying Soiling Accumulation on Photovoltaic Modules Using Standard Testing Results
Equipment named: Pasan solar simulator IIIb with class AAA. Application: STC performance measurement for soiling quantification.
- Accredited testing2014SUPSI-ISAAC PVLab, CanobbioSwitzerland
Optimization of thin film module testing and PV module energy rating at SUPSI (Annual Report 2014)
Equipment named: Pasan IIIa and Pasan IIIb solar simulators (IIIb upgraded with LED floodlights for spectral tuning). Application: Spectral responsivity (27 filters on Pasan IIIa) and spectro-metric I-V of multi-junction modules on Pasan IIIb (accredited-lab procedure development).
- Accredited testing2010Photovoltaik Institut Berlin (PI Berlin)Germany
Actual issues on power measurement of photovoltaic modules
Equipment named: Pasan SSIIIb (class A, 3.0 m x 3.0 m). Application: Reference simulator at PI Berlin in a study of uniformity, spectral mismatch, tandem current mismatch and sweep-time (transient) effects on Pmax of crystalline and thin-film modules (a-Si, micromorph tandem, CIGS).
- Accredited testing2006Korea Institute of Energy Research (KIER)South Korea
Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test
Equipment named: Pasan IIIb. Application: Domestic certification testing of PV modules; uncertainty analysis of I-V testing.
- Characterisation2026CEA Liten, Campus INES; Universidad de Antofagasta (CDEA); Universidad de Granada; Universidad Tecnica Federico Santa Maria (author affiliations)France
Assessment of Soiling Dynamics and Cleaning Efficiency for Photovoltaic Modules Under Different Dust Environments
Equipment named: Class A+ PASAN solar simulator. Application: STC I-V characterisation (Isc, Pmax) of single-cell SHJ laminates before and after accelerated soiling and cleaning
- Characterisation2024Not stated; all authors Universidade Federal do Rio Grande do Sul, Laboratório de Energia SolarBrazil (author affiliations)
Análise dos Coeficientes Térmicos de Módulos Fotovoltaicos Bifaciais Utilizando Simulador Solar e Iluminação Natural
Equipment named: SunSim 3c simulator from the Swiss company Pasan, with a purpose-built thermostatic chamber. Application: Indoor vs outdoor determination of temperature coefficients alpha, beta and gamma of a bifacial module, 25 to 65 °C at 1000 W/m2
- Characterisation2021ZHAW Zurich University of Applied Sciences (Swiss Mobile Flasher Bus)Switzerland
Long-term power degradation analysis of crystalline silicon PV modules using indoor and outdoor measurement techniques
Equipment named: PASAN sun simulator 3c (installed in the Swiss Mobile Flasher Bus). Application: Indoor-type STC flasher measurements of fielded modules over years for degradation-rate analysis; mobile on-site testing.
- Characterisation2018LABSOL, UFRGSBrazil
CORREÇÃO ESPECTRAL E ANÁLISE DA INSTABILIDADE TEMPORAL EM SIMULADOR SOLAR PARA ENSAIOS DE MÓDULOS FOTOVOLTAICOS
Equipment named: SunSim 3C (PASAN, Meyer Burger Group). Application: Spectral mismatch correction with technology-matched reference cells and temporal-instability check of the simulator.
- Characterisation2016CEA-INES Photovoltaic Modules Laboratory, Le Bourget-du-Lac; CNRS IMEP-LAHC, Grenoble Alpes University (author affiliations)France
A study of the annual performance of bifacial photovoltaic modules in the case of vertical facade integration
Equipment named: PASAN solar simulator (spectral class A+ per the authors' measurement). Application: Double-illumination (front and rear, mirrors) I-V characterisation of bifacial mini-modules; ray-tracing model of the simulator used to design the setup
- Characterisation2016Eurac Research laboratory, Bolzano (measurements for Politecnico di Milano)Italy
The first Italian BIPV project: Case study and long-term performance analysis
Equipment named: PASAN testing chamber. Application: STC I-V of modules removed from a 20-year-old BIPV array (IEC 60904).
- Characterisation2014ENEA C.R. Portici laboratory, as statedItaly
Energy Rating for Different Module Technologies
Equipment named: Solar simulator Pasan IIIB class AAA+ (realized by Belval). Application: STC flash test of mono-Si, multi-Si, quasi-mono and CIGS modules before outdoor energy-rating measurements
- Research2022European Commission JRC, ESTI, IspraItaly
Implementation of the IEC TS 60904-1-2 Measurement Methods for Bifacial Silicon PV Devices
Equipment named: class AAA PASAN IIIB PSS (pulse length of 10 ms). Application: Single-side illumination I-V measurements of bifacial devices (multiflash method) for IEC TS 60904-1-2 implementation.
- Research2021AIT Austrian Institute of Technology, Vienna (experimental part); TU WienAustria
Purely electrical power stabilization of photovoltaic technologies
Equipment named: PASAN Flasher (class AAA pulsed solar simulator manufactured by PASAN). Application: STC I-V measurement of full-size CIGS and c-Si modules before/after dark-bias stabilisation experiments.
- Research2017Not stated; authors CREST, Loughborough UniversityUnited Kingdom (author affiliations)
Uncertainty contributions in photocurrent linearity measurements of PV devices using a flash solar simulator
Equipment named: Pasan 3B flash solar simulator, modified with an external 16 bit data acquisition system and four attenuation masks. Application: Photocurrent linearity measurement of PV devices from cells to full modules, with Monte Carlo uncertainty analysis
- Research2016European Commission JRC, ESTI, IspraItaly
Determination of internal series resistance of PV devices: repeatability and uncertainty
Equipment named: Pasan IIIB. Application: I-V curves at multiple irradiances for series-resistance determination (IEC 60891), compared across three large-area simulators.
- Research2015University of Glasgow; Solar Energy Research Institute of Singapore (SERIS), NUS; REC Cells Pte Ltd (author affiliations)Singapore
A Linear Identification of Diode Models from Single I-V Characteristics of PV Panels
Equipment named: Pulsed solar simulator (PASAN IIIB), about 12 ms constant-intensity plateau. Application: Indoor flash I-V measurement of full-size commercial modules to validate a diode-model parameter extraction method
- Research2012SUPSI (University of Applied Sciences and Arts of Southern Switzerland), as stated: the reference load is "available at SUPSI and part of its ISO-17025 accreditation system"Switzerland
Fast and accurate methods for the performance testing of highly-efficient c-Si photovoltaic modules using a 10 ms single-pulse solar simulator and customized voltage profiles
Equipment named: Pasan IIIB solar simulator (flash unit); Pasan BV66 electronic load; Pasan HIGH-LIGHT (HL) electronic load. Application: STC I-V testing of highly capacitive high-efficiency c-Si modules (HIT, back-contact) in one 10 ms flash with customized "dragon-back" voltage profiles, validated against multi-flash reference measurements
- Research2011Oerlikon Solar (text: 'With installation at Oerlikon's site'; site not specified); author affiliations Oerlikon Solar-Lab SA (Neuchâtel), Oerlikon Solar AG (Trübbach), Photovoltaic Consultant (Freiburg)Switzerland (author affiliations)
Traceable Flasher-Based Power Measurement of Micromorph Tandem Modules
Equipment named: commercial solar simulator SunSim IIIb (Pasan SA, CH), modified for tunable spectrum with a longitudinal sliding test bed. Application: Spectral balancing by lamp intensity and distance, with PTB-calibrated top and bottom component reference cells, for traceable STC power measurement of Micromorph tandem modules