All products
Flagship platforms
Full range
Explore
Get in touch

Fast and accurate methods for the performance testing of highly-efficient c-Si photovoltaic modules using a 10 ms single-pulse solar simulator and customized voltage profiles

Alessandro Virtuani et al.

Institution
SUPSI (University of Applied Sciences and Arts of Southern Switzerland), as stated: the reference load is "available at SUPSI and part of its ISO-17025 accreditation system", Switzerland
Equipment named
Pasan IIIB solar simulator (flash unit); Pasan BV66 electronic load; Pasan HIGH-LIGHT (HL) electronic load
Application
STC I-V testing of highly capacitive high-efficiency c-Si modules (HIT, back-contact) in one 10 ms flash with customized "dragon-back" voltage profiles, validated against multi-flash reference measurements
Use
Research
Published uncertainty
±2.4% (k=2) on Pmax for c-Si modules with the conventional (BV66) set-up; dragon-back vs multi-flash Pmax differences below ±0.5%
Technologies
High-efficiency c-Si, HJT, Back contact
Venue
Measurement Science and Technology, 2012

Significance

Validates the dragon-back customized voltage profile method for measuring highly capacitive modules within a single 10 ms flash, the origin of the Pasan DragonBack method. Pasan staff are authors or co-authors of this work; it is Pasan research, not independent validation.

From the source

“IV testing of a set of PV modules was performed at standard test conditions ... using a Pasan IIIB solar simulator (flash unit) and two different electronic loads (EL) developed by Pasan”

Read the source

This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.

All entries