- Institution
- ZHAW (Swiss Mobile Flasher Bus) with JRC ESTI, Switzerland / Italy
- Equipment named
- Pasan 3c flasher (10 ms pulse) in the Swiss Mobile Flasher Bus
- Application
- Intercomparison of mobile on-site module power measurement against ESTI's stationary calibration laboratory.
- Use
- Intercomparison
- Published uncertainty
- Mobile flasher +/-3%; agreement within +/-0.2% for a poly-Si module, within the larger 2.0% (k=2) interval
- Technologies
- Crystalline silicon
- Topics
- Venue
- 26th EU PVSEC, Hamburg, 2011
Significance
Shows a Pasan 3c in a truck-mounted lab agreeing with the ESTI calibration laboratory to within +/-0.2% on polycrystalline modules.
From the source
“The SMFB equipped with a Pasan 3c flasher applied a 10ms irradiance pulse”
This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.