- Institution
- CEA-INES Photovoltaic Modules Laboratory, Le Bourget-du-Lac; CNRS IMEP-LAHC, Grenoble Alpes University (author affiliations), France
- Equipment named
- PASAN solar simulator (spectral class A+ per the authors' measurement)
- Application
- Double-illumination (front and rear, mirrors) I-V characterisation of bifacial mini-modules; ray-tracing model of the simulator used to design the setup
- Use
- Characterisation
- Published uncertainty
- 3-sigma relative uncertainty of IV parameters within +/-3% (reproducibility study)
- Technologies
- Bifacial, BIPV
- Topics
- Venue
- Energy Science & Engineering 4(1), 52-68, 2016
Significance
Uses a double-illumination setup inside a Pasan solar simulator, with a ray-tracing model of the simulator, to characterise bifacial modules for vertical facade integration.
From the source
“Figure 3. Picture of the double illumination setup positioned in our PASAN solar simulator.”
This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.