- Institution
- University of Glasgow; Solar Energy Research Institute of Singapore (SERIS), NUS; REC Cells Pte Ltd (author affiliations), Singapore
- Equipment named
- Pulsed solar simulator (PASAN IIIB), about 12 ms constant-intensity plateau
- Application
- Indoor flash I-V measurement of full-size commercial modules to validate a diode-model parameter extraction method
- Use
- Research
- Published uncertainty
- Overall uncertainty of module power measurement within +/-2% (coverage not stated)
- Technologies
- Crystalline silicon
- Topics
- Venue
- IEEE Transactions on Industrial Electronics 62(7), 4181-4193, 2015
Significance
Validates a linear diode-parameter identification method on module I-V curves measured on a Pasan IIIB.
From the source
“The I-V characteristics of full-sized commercial modules were measured indoor by a pulsed solar simulator (PASAN IIIB) with a constant illumination intensity plateau of about 12 ms used.”
This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.