- Institution
- CIEMAT (Madrid), Fraunhofer ISE (Freiburg) and SUPSI (Lugano), as stated in Table 1, Spain / Germany / Switzerland
- Equipment named
- Belval, Pasan IIIb (CIEMAT, Fraunhofer ISE); Belval, Pasan IIIa (SUPSI)
- Application
- Round-robin STC power measurement of five crystalline silicon module types, high-efficiency modules included, among six European test laboratories (PERFORMANCE project); single-flash and multi-flash techniques
- Use
- Intercomparison
- Technologies
- Crystalline silicon, High-efficiency c-Si
- Topics
- Venue
- Proceedings of the 22nd European Photovoltaic Solar Energy Conference and Exhibition, Milan, 2007
Significance
Three of six participating European laboratories measured on Pasan simulators in this PERFORMANCE round robin, which found a 2% Pmax spread.
From the source
“Ciemat Belval, Pasan IIIb I-V measurement with pulsed solar simulator ... ISE Belval, Pasan IIIb ... SUPSI Belval, Pasan IIIa Single-flash I-V measurement with pulsed solar simulator”
This entry summarises a third-party publication. It does not imply that the institution or the authors endorse Pasan SA or its products.