The measurement problem
A module measured straight out of storage may be in a state it never has in the field. For thin film, preconditioning is the dominant cause of disagreement between reference laboratories [3]; for TOPCon after UV exposure, dark-storage metastability can be read as degradation [4].
The physics behind it
- Crystalline silicon: boron-oxygen light-induced degradation and LeTID [5]; stabilisation research for IEC 61215 [6].
- Amorphous silicon: Staebler-Wronski degradation, partly reversible by annealing [7].
- CdTe and CIGS: reversible changes with light, bias and temperature, relaxation in the dark [8]; the light-stabilised state depends on exposure temperature [2].
- TOPCon after UV: a metastable dark loss recovering within minutes under light [9].
- Perovskite: ion migration over seconds to minutes and fatigue over light-dark cycles [10].
What the measurement must achieve
- Use the stabilisation of the technology-specific part of IEC 61215 or a validated alternative, and report it.
- Control the module temperature during exposure and record it.
- Fix the delay between the end of exposure and the flash.
- Validate any bias-based method against light stabilisation for each product [11].
- Monitor irradiance stability during the soak: IEC 60904-9 defines long-term instability for irradiation exposure from at least 100 readings [12].
Applicable standards
| Standard | What it governs here |
|---|---|
| IEC 61215-2:2021Terrestrial PV modules, design qualification and type approval: test procedures | MQT 19 stabilisation: light-induced and other procedures, initial and final stabilisation, BO-LID. |
| IEC 61215-1-1:2021Special requirements for crystalline silicon modules | c-Si criterion x = 0.01, initial stabilisation at least 10 kWh/m² in two intervals of at least 5 kWh/m². |
| IEC 61215-1-2:2021Special requirements for thin-film cadmium telluride (CdTe) modules | CdTe stabilisation. |
| IEC 61215-1-3:2021Special requirements for thin-film amorphous silicon modules | Amorphous silicon stabilisation. |
| IEC 61215-1-4:2021Special requirements for thin-film Cu(In,Ga)(S,Se)2 (CIGS) modules | CIGS stabilisation and dark-soak rules. |
| IEC 60904-9:2020 (edition 3)Classification of solar simulator characteristics | Long-term instability for irradiation exposure. |
| ISOS protocols (Khenkin et al., 2020)Consensus statement for stability assessment and reporting of perovskite photovoltaic devices | Light-soaking protocols (ISOS-L) for perovskite stability. |
Measurement technologies: advantages and limitations
Steady-state light sources (LED or lamps) perform the soak; LED offers closed-loop irradiance and a stable spectrum, lamps a broadband spectrum including UV, which matters where recovery is wavelength dependent [13]. Current injection in the dark is fast and weather independent: it held CIGS modules within 1 % [14], while one bias-only method failed validation on CdTe [11]. The I-V measurement after the soak can be pulsed or steady state.
Where Pasan equipment fits
- LED Light SoakerContinuous, closed-loop regulated LED light on full-size modules, MPP, short-circuit or open-circuit bias, 1 Hz log of current, voltage and irradiance, programmable soak steps.
- HighLIGHT 100ms LabOptional current-injection preconditioning with the flash a fraction of a second after the injection (CdTe).
Technical questions
- What does MQT 19 require for crystalline silicon?
- At least 10 kWh/m² of light exposure, in two intervals of at least 5 kWh/m², until the power changes by less than 1 % (criterion x = 0.01) [1].
- Is current injection an alternative to light soaking?
- Only once validated against light stabilisation for that product. It worked for CIGS [14]; one method failed for CdTe [11].
- Does the temperature during soaking matter?
- Yes, for thin film the stabilised state can differ by 5.8 % for 20 °C [2].
References
- , “IEC 61215-1:2021, IEC 61215-1-1:2021 and IEC 61215-2:2021, Terrestrial photovoltaic modules: design qualification and type approval”, International Electrotechnical Commission, 2021. Source
- , “Temperature-dependent light-stabilized states in thin-film PV modules”, 42nd IEEE Photovoltaic Specialists Conference, 2015. doi:10.1109/PVSC.2015.7355854
- , “Improvements in world-wide intercomparison of PV module calibration”, Solar Energy 155, 1451-1461, 2017. doi:10.1016/j.solener.2017.07.081
- , “UV-induced degradation: comparative analysis of PV module testing and stabilization procedures against outdoor behavior”, EPJ Photovoltaics 17, 15, 2026. doi:10.1051/epjpv/2026007
- , “Progress in the understanding of light- and elevated temperature-induced degradation in silicon solar cells: a review”, Progress in Photovoltaics 29, 1180-1201, 2021. doi:10.1002/pip.3362
- , “Stabilization of light-induced effects in Si modules for IEC 61215 design qualification”, Solar Energy 208, 894-904, 2020. doi:10.1016/j.solener.2020.08.025
- , “Reversible conductivity changes in discharge-produced amorphous Si”, Applied Physics Letters 31, 292-294, 1977. doi:10.1063/1.89674
- , “Metastable electrical characteristics of polycrystalline thin-film photovoltaic modules upon exposure and stabilization”, Journal of Photonics for Energy 2, 022001, 2012. doi:10.1117/1.JPE.2.022001
- , “UV-induced degradation and associated metastability in TOPCon photovoltaic modules: understanding kinetics and cell variance”, Progress in Photovoltaics 34, 589-599, 2026. doi:10.1002/pip.70067
- , “Consensus statement for stability assessment and reporting for perovskite photovoltaics based on ISOS procedures”, Nature Energy 5, 35-49, 2020. doi:10.1038/s41560-019-0529-5
- , “Robust measurement of thin-film photovoltaic modules exhibiting light-induced transients”, Proc. SPIE 9561, 956108, 2015. doi:10.1117/12.2188827
- , “IEC 60904-9:2020, Photovoltaic devices, Part 9: Classification of solar simulator characteristics (edition 3.0)”, International Electrotechnical Commission, 2020. Source