On-site module testing for utility-scale PV plants

On site, module power can be checked outdoors with I-V tracers and translation to STC (IEC 61829) or with a mobile indoor flasher, to which the laboratory requirements of IEC 60904-1 and -9 apply unchanged; electroluminescence finds defects but does not measure power (IEC TS 60904-13), and no peer-reviewed comparison of mobile and accredited laboratory uncertainty was found, so a mobile result should carry the operator's own budget.

The measurement problem

Owners want to verify delivered or aged module power at the plant. Outdoor tracing depends on weather and translation; mobile flashers bring laboratory conditions to site but run in vehicles exposed to temperature, vibration and transport.

The physics behind it

  • Outdoors, irradiance, spectrum, angle of incidence and temperature vary, and translation uncertainty grows with distance from STC; uncertainties of outdoor characterisation and outdoor reference module calibration have been analysed [1].
  • Fast field I-V tracers can show capacitive hysteresis on modern modules; one sub-5 ms method needed transient correction [2].
  • Daylight, drone-based EL has been demonstrated near one sun [3]; outdoor EL and PL methods are reviewed in [4].

What the measurement must achieve

  • On-site array I-V per IEC 61829:2015, with translation to STC per IEC 60891 [5].
  • Commissioning documentation and tests per IEC 62446-1.
  • For mobile indoor flashers: the same IEC 60904-1 and -9 requirements, a reference module travelling with the system, temperature control and a documented uncertainty budget.
  • EL per IEC TS 60904-13 for defects, kept separate from power claims.

Applicable standards

Applicable standards
StandardWhat it governs here
IEC 61829:2015PV array: on-site measurement of current-voltage characteristicsOn-site I-V of modules and arrays.
IEC 62446-1:2016+AMD1:2018Grid-connected PV systems: documentation, commissioning tests and inspectionCommissioning tests and documentation.
IEC TS 60904-13:2018Electroluminescence of photovoltaic modulesElectroluminescence imaging.
IEC 60891:2021Procedures for temperature and irradiance corrections to measured I-V characteristicsTranslation of field I-V curves to STC.
IEC 60904-9:2020 (edition 3)Classification of solar simulator characteristicsClassification of a mobile simulator, as of any simulator.

Measurement technologies: advantages and limitations

Mobile pulsed xenon is compact with a low heat load; mobile LED offers electronic irradiance control and no lamp replacement, but needs per-channel calibration and thermal stabilisation in a vehicle. Capacitive limits apply in the field exactly as in the laboratory.

Where Pasan equipment fits

  • Mobile LabA calibrated flasher, contacting and electroluminescence imaging in a van, trailer or container (an Avalon ST platform), for incoming inspection, warranty disputes and audits on site.
  • Rent a LabMobile flash-test laboratories for rent.
  • Pasan ServicesIndependent module measurement at the factory and on arrival.

Technical questions

Which standard covers on-site I-V curves?
IEC 61829:2015 for arrays, with translation per IEC 60891 [5].
Is field EL a power measurement?
No. IEC TS 60904-13 covers image capture, processing and qualitative interpretation.
Do laboratory requirements apply to a mobile flasher?
Yes, IEC 60904-1 and 60904-9 apply unchanged; no separate mobile-laboratory standard was found.
Why do fast field I-V tracers disagree with laboratory values on modern modules?
Short sweeps cause capacitive hysteresis [2].

References

  1. J. M. Carrillo et al., “Uncertainties on the outdoor characterization of PV modules and the calibration of reference modules”, Solar Energy 155, 880-892, 2017. doi:10.1016/j.solener.2017.07.028
  2. E. Ortega et al., “Photovoltaic modules transient response analysis and correction under a fast characterization system”, Solar Energy, 2021. doi:10.1016/j.solener.2021.03.032
  3. G. Alves dos Reis Benatto et al., “Drone-based daylight electroluminescence imaging of PV modules”, IEEE Journal of Photovoltaics 10, 872-877, 2020. doi:10.1109/JPHOTOV.2020.2978068
  4. A. Redondo-Plaza et al., “Inspection techniques in photovoltaic power plants: a review of electroluminescence and photoluminescence imaging”, Renewable Energies 2, 2024. doi:10.1177/27533735241282603
  5. IEC, “IEC 61829:2015, Photovoltaic (PV) array: on-site measurement of current-voltage characteristics”, International Electrotechnical Commission, 2015. Source
Related pages
Production-line simulationGuide: EL testing of PV modules

How this page is written: claims about physics and standards cite published sources, claims about Pasan equipment repeat only what the product pages state, and no other manufacturer is named. Editorial method

Rather we contact you?

Leave your email and we will get back to you. No form to fill in.

We only use your address to answer you. Privacy policy