The measurement problem
Owners want to verify delivered or aged module power at the plant. Outdoor tracing depends on weather and translation; mobile flashers bring laboratory conditions to site but run in vehicles exposed to temperature, vibration and transport.
The physics behind it
- Outdoors, irradiance, spectrum, angle of incidence and temperature vary, and translation uncertainty grows with distance from STC; uncertainties of outdoor characterisation and outdoor reference module calibration have been analysed [1].
- Fast field I-V tracers can show capacitive hysteresis on modern modules; one sub-5 ms method needed transient correction [2].
- Daylight, drone-based EL has been demonstrated near one sun [3]; outdoor EL and PL methods are reviewed in [4].
What the measurement must achieve
- On-site array I-V per IEC 61829:2015, with translation to STC per IEC 60891 [5].
- Commissioning documentation and tests per IEC 62446-1.
- For mobile indoor flashers: the same IEC 60904-1 and -9 requirements, a reference module travelling with the system, temperature control and a documented uncertainty budget.
- EL per IEC TS 60904-13 for defects, kept separate from power claims.
Applicable standards
| Standard | What it governs here |
|---|---|
| IEC 61829:2015PV array: on-site measurement of current-voltage characteristics | On-site I-V of modules and arrays. |
| IEC 62446-1:2016+AMD1:2018Grid-connected PV systems: documentation, commissioning tests and inspection | Commissioning tests and documentation. |
| IEC TS 60904-13:2018Electroluminescence of photovoltaic modules | Electroluminescence imaging. |
| IEC 60891:2021Procedures for temperature and irradiance corrections to measured I-V characteristics | Translation of field I-V curves to STC. |
| IEC 60904-9:2020 (edition 3)Classification of solar simulator characteristics | Classification of a mobile simulator, as of any simulator. |
Measurement technologies: advantages and limitations
Mobile pulsed xenon is compact with a low heat load; mobile LED offers electronic irradiance control and no lamp replacement, but needs per-channel calibration and thermal stabilisation in a vehicle. Capacitive limits apply in the field exactly as in the laboratory.
Where Pasan equipment fits
- Mobile LabA calibrated flasher, contacting and electroluminescence imaging in a van, trailer or container (an Avalon ST platform), for incoming inspection, warranty disputes and audits on site.
- Rent a LabMobile flash-test laboratories for rent.
- Pasan ServicesIndependent module measurement at the factory and on arrival.
Technical questions
- Which standard covers on-site I-V curves?
- IEC 61829:2015 for arrays, with translation per IEC 60891 [5].
- Is field EL a power measurement?
- No. IEC TS 60904-13 covers image capture, processing and qualitative interpretation.
- Do laboratory requirements apply to a mobile flasher?
- Yes, IEC 60904-1 and 60904-9 apply unchanged; no separate mobile-laboratory standard was found.
- Why do fast field I-V tracers disagree with laboratory values on modern modules?
- Short sweeps cause capacitive hysteresis [2].
References
- , “Uncertainties on the outdoor characterization of PV modules and the calibration of reference modules”, Solar Energy 155, 880-892, 2017. doi:10.1016/j.solener.2017.07.028
- , “Photovoltaic modules transient response analysis and correction under a fast characterization system”, Solar Energy, 2021. doi:10.1016/j.solener.2021.03.032
- , “Drone-based daylight electroluminescence imaging of PV modules”, IEEE Journal of Photovoltaics 10, 872-877, 2020. doi:10.1109/JPHOTOV.2020.2978068
- , “Inspection techniques in photovoltaic power plants: a review of electroluminescence and photoluminescence imaging”, Renewable Energies 2, 2024. doi:10.1177/27533735241282603
- , “IEC 61829:2015, Photovoltaic (PV) array: on-site measurement of current-voltage characteristics”, International Electrotechnical Commission, 2015. Source
How this page is written: claims about physics and standards cite published sources, claims about Pasan equipment repeat only what the product pages state, and no other manufacturer is named. Editorial method




